skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of Fusion Imaging Using a Combined SPECT/CT System and Intra-arterial CT: Assessment of Drug Distribution by an Implantable Port System in Patients Undergoing Hepatic Arterial Infusion Chemotherapy

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ; ; ;  [1]; ; ;  [2]
  1. Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, Department of Diagnostic Radiology (Japan)
  2. Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, Gastroenterological Surgery (Japan)

Hepatic arterial infusion (HAI) chemotherapy is effective for treating primary and metastatic carcinoma of the liver. We compared the perfusion patterns of HAI chemotherapy on intra-arterial port-catheter computed tomography (iapc-CT) and fused images obtained with a combined single-photon emission computed tomography/computed tomography (SPECT/CT) system. We studied 28 patients with primary or metastatic carcinoma of the liver who bore an implantable HAI port system. All underwent abdominal SPECT using Tc-99m-MAA (185 Mbq); the injection rate was 1 mL/min, identical to the chemotherapy infusion rate, and 0.5 mL/sec for iapc-CT. Delivery was through an implantable port. We compared the intrahepatic perfusion (IHP) and extrahepatic perfusion (EHP) patterns of HAI chemotherapy on iapc-CT images and fused images obtained with a combined SPECT/CT system. In 23 of 28 patients (82%), IHP patterns on iapc-CT images and fused images were identical. In 5 of the 28 patients (18%), IHP on fusion images was different from IHP on iapc-CT images. EHP was seen on fused images in 12 of the 28 patients (43%) and on iapc-CT images in 8 patients (29%). In 17 patients (61%), upper gastrointestinal endoscopy revealed gastroduodenal mucosal lesions. EHP was revealed on fused images in 10 of these patients; 9 of them manifested gastroduodenal toxicity at the time of subsequent HAI chemotherapy. Fusion imaging using the combined SPECT/CT system reflects the actual distribution of the infused anticancer agent. This information is valuable not only for monitoring adequate drug distribution but also for avoiding potential extrahepatic complications.

OSTI ID:
21091219
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 29, Issue 3; Other Information: DOI: 10.1007/s00270-005-0268-9; Copyright (c) 2006 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English