Title: 'Recovery{sup TM}' Vena Cava Filter: Experience in 96 Patients

Journal Article · · Cardiovascular and Interventional Radiology

The purpose of the study was to assess the clinical safety and efficacy of the 'Recovery{sup TM}' (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a 'Recovery{sup TM}' IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. 'Recovery' filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean: 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following 'Recovery' filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.

OSTI ID:
21091173
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 29, Issue 4; Other Information: DOI: 10.1007/s00270-005-0271-1; Copyright (c) 2006 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter
Journal Article · Fri Apr 15 00:00:00 EDT 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21091173

Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter
Journal Article · Thu Apr 15 00:00:00 EDT 2010 · Cardiovascular and Interventional Radiology · OSTI ID:21091173

The Guenther temporary inferior vena cava filter for short-term protection against pulmonary embolism
Journal Article · Sat Mar 15 00:00:00 EST 1997 · Cardiovascular and Interventional Radiology · OSTI ID:21091173