Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

Journal Article · · Cardiovascular and Interventional Radiology
; ;  [1]
  1. Nottingham CityHospital, Hucknall Road, Nottingham NG7 2UH, Department of Radiology (United Kingdom)

We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.

OSTI ID:
21088321
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 1 Vol. 27; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

A Novel Technique for Inferior Vena Cava Filter Extraction
Journal Article · Thu May 02 00:00:00 EDT 2013 · Cardiovascular and Interventional Radiology · OSTI ID:22318122

Laceration of the inferior vena cava of angiographic demonstration
Journal Article · Mon Aug 01 00:00:00 EDT 1983 · Cardiovasc. Interv. Radiol.; (United States) · OSTI ID:5350626

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval
Journal Article · Wed Jan 14 23:00:00 EST 2009 · Cardiovascular and Interventional Radiology · OSTI ID:21426324