Is Lower-Dose Digital Fluorography Diagnostically Adequate Compared with Higher-Dose Digital Radiography for the Diagnosis of Fallopian Tube Stenosis?

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709910025· OSTI ID:21083667
;  [1];  [2];  [1]
  1. Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)
  2. Department of Medical Information and Medical Records, Nagoya University School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)

Purpose: In an effort to reduce patient radiation dose during selective fallopian tube catheterization, the diagnostic adequacy of fluoroscopic images was compared with digital radiographic images in both a phantom study and a clinical study.Methods: For the phantom study polyethylene tubes with inner diameters of 1.30, 0.95, 0.80, 0.57, and 0.45 mm were used. Randomly selected tubes with/without stenoses, recorded by digital radiographic and last-image hold fluoroscopic images, were presented to five blinded radiologists, and receiver-operating characteristic (ROC) analyses were performed. For the clinical study tubal visualization as well as detectability of stenoses and occlusions were analyzed in 14 women using a 2-way analysis of variance for nonrepeated measures.Results: The phantom study showed no significant differences between the two imaging techniques for 0.57-mm-diameter and larger tubes; in contrast, fluoroscopic images provided significantly lower detectability of stenoses in 0.45-mm-diameter tubes (p < 0.05). The clinical study showed inferior tubal visualization and diagnostic performance for fluoroscopic images.Conclusions: Although fluoroscopic images have inferior diagnostic capability in detection of tubal stenoses and occlusions, these images may be adequate for documenting tubal patency with spill into the peritoneal cavity.

OSTI ID:
21083667
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 2 Vol. 23; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Fluoroscopically Guided Transcervical Fallopian Tube Recanalization of Post-Sterilization Reversal Mid-Tubal Obstructions
Journal Article · Tue Mar 14 23:00:00 EST 2000 · Cardiovascular and Interventional Radiology · OSTI ID:21083659

Radiographic fallopian tube recanalization: Absorbed ovarian radiation dose
Journal Article · Mon Jul 01 00:00:00 EDT 1991 · Radiology; (United States) · OSTI ID:5591853

Hysterosalpingography using a flat panel unit: Evaluation and optimization of ovarian radiation dose
Journal Article · Sun Jul 15 00:00:00 EDT 2012 · Medical Physics · OSTI ID:22100646