Laboratory Investigations [cmFragmentation of Pulmonary Emboli: In Vivo Experimental Evaluation of Two High-Speed Rotating Catheters]
Journal Article
·
· Cardiovascular and Interventional Radiology
- Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, D-52057 Aachen (Germany)
- Institute of Pathology, University of Technology Aachen, Pauwelsstrasse 30, D-52057 Aachen (Germany)
Purpose: To test two over-the-wire systems for fragmentation of pulmonary emboli. Methods: In 11 dogs, 22 embolic occlusions of lobar or central pulmonary arteries were performed by injection of preformed emboli through a jugular vein sheath. A commercially available device (thrombolizer) and a modified version of the impeller catheter were introduced via the femoral vein and positioned at the embolus site. Results: Catheter placement at the site of the emboli was possible. In more than half of the cases a hydrophilic or an extra-stiff guidewire was necessary. The thrombolizer did not rotate properly with its original pneumatic drive and required a major modification. When sufficient rotation was provided, both fragmentation catheters were able to clear the occluded main arteries. Side branches were partly obstructed by the resulting fragments. Recanalization led to a reduction of the emboli-induced elevation of the pulmonary arterial pressure by two-thirds. Histology of the recanalized pulmonary artery segments revealed localized (impeller catheter) and widespread (thrombolizer) periarterial hemorrhage. Conclusion: Embolus fragmentation led to a hemodynamic improvement. The impeller catheter was less traumatic compared with the thrombolizer, which was technically insufficient.
- OSTI ID:
- 21080532
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 3 Vol. 19; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Simulated Flow Pattern in Massive Pulmonary Embolism: Significance for Selective Intrapulmonary Thrombolysis
Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters
Experimental Impeller Fragmentation of Iliocaval Thrombosis Under Tulip Filter Protection: Preliminary Results
Journal Article
·
Fri May 15 00:00:00 EDT 1998
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080409
Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters
Journal Article
·
Fri Feb 14 23:00:00 EST 2014
· Cardiovascular and Interventional Radiology
·
OSTI ID:22318114
Experimental Impeller Fragmentation of Iliocaval Thrombosis Under Tulip Filter Protection: Preliminary Results
Journal Article
·
Mon Apr 15 00:00:00 EDT 1996
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080521