Title: Dilatation Mechanism of Balloon Angioplasty in Children: Assessment by Angiography and Intravascular Ultrasound

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900224· OSTI ID:21080432
; ; ; ; ;  [1]; ;  [2]
  1. Department of Pediatrics, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113 (Japan)
  2. Department of Thoracic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113 (Japan)

Purpose: Little information is available about the dilatation mechanism in children. This prospective study aimed to (1) evaluate the dilatation mechanism of balloon angioplasty in children with arterial stenosis, and (2) compare the morphological changes seen by intravascular ultrasound (IVUS) and angiography. Methods: Twenty consecutive patients, who had undergone a total of 23 procedures, were examined before and immediately after balloon angioplasty with a 4.3 Fr, 30 MHz rotational tip IVUS system. The lesions for IVUS study had resulted from coarctation of the aorta in six patients, pulmonary arterial stenosis in five, Blalock-Taussig shunt stenosis in three, subclavian artery stenosis in two, renal artery stenosis in two, coronary artery stenosis in one and ductus arteriosus in one. Results: Four distinctive morphological types were identified: type I with arterial stretching, type IIa with superficial tearing, type IIb with deep intimal-medial tearing, type III with flap formation, and type IV with dissection. The diameter of the narrowest site before and after balloon angioplasty increased significantly from 2.1 {+-} 1.4 mm to 4.6 {+-} 3.4 mm (p < 0.001). Eighteen of the 23 angioplasty procedures (78%) were considered to be successful, with a dilatation ratio of more than 50%. In most patients with successful dilatation, non-stretch mechanisms such as tearing, flap formation, or dissection were found. The positive percent (70%) of non-stretch mechanisms seen by IVUS was significantly higher than the positive findings (39%) by angiography ({chi}{sup 2}= 6.47, p < 0.02). Conclusions: Non-stretch morphology of the arterial wall may be a common mechanism of dilatation after balloon angioplasty in children with arterial stenosis. IVUS is a useful modality for evaluating the effectiveness of balloon angioplasty and the mechanism of dilatation in individual cases.

OSTI ID:
21080432
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 21, Issue 2; Other Information: DOI: 10.1007/s002709900224; Copyright (c) 1998 Springer-Verlag New York Inc; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Intravascular Ultrasound Imaging of Peripheral Arteries as an Adjunct to Balloon Angioplasty and Atherectomy
Journal Article · Fri Nov 15 00:00:00 EST 1996 · Cardiovascular and Interventional Radiology · OSTI ID:21080432

Intravascular Ultrasound and Histology in In Vitro Assessment of Iliac Artery Angioplasty
Journal Article · Fri Jan 15 00:00:00 EST 1999 · Cardiovascular and Interventional Radiology · OSTI ID:21080432

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery
Journal Article · Thu Dec 15 00:00:00 EST 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21080432