Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Nonlinear Geometric Warping of the Mask Image: A New Method for Reducing Misregistration Artifacts in Digital Subtraction Angiography

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900230· OSTI ID:21080431
; ; ; ; ; ; ; ; ;  [1];  [2]; ;  [3]
  1. Department of Radiology, Fukui Medical School, 23 Shimoaizuki, Matsuoka-cho, Yoshida-gun, Fukui 910-11 (Japan)
  2. Department of Information Science, University of Fukui, 3-9-1 Bunkyou, Fukui 910 (Japan)
  3. Department of Neurosurgery, Fukui Medical School, 23 Shimoaizuki, Matsuoka-cho, Yoshida-gun, Fukui 910-11 (Japan)
Purpose: Misregistration artifact is the major cause of image degradation in digital subtraction angiography (DSA). The purpose of this study was to evaluate the efficacy of a newly developed nonlinear geometric warping method to reduce misregistration artifact in DSA. Methods: The processing of the images was carried out on a workstation with a fully automatic computerized program. After making differential images with a lapracian filter, 49 regions of interest (ROIs) were set in the image to be processed. Each ROI of the live image scanned the corresponding ROI of the mask image searching for the best position to match itself. Each pixel of the mask image was shifted individually following the data calculated from the shifts of the ROIs. Five radiologists compared the images produced by the conventional parallel shift technique and those processed with this new method in 16 series of cerebral DSA. Results: In 14 of 16 series (88%), more radiologists judged the images processed with the new method to be better in quality. Small arteries near the skull base and veins of low density were clearly visualized in the images processed by the new method. Conclusion: This newly proposed method could be a simple and practical way to automatically reduce misregistration artifacts in DSA.
OSTI ID:
21080431
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 2 Vol. 21; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Beam attenuation devices for digital subtraction angiography
Journal Article · Fri Nov 30 23:00:00 EST 1984 · Radiology; (United States) · OSTI ID:5615556

Digital angiography: matched filtration versus mask-mode subtraction
Journal Article · Mon Dec 31 23:00:00 EST 1984 · Radiology; (United States) · OSTI ID:5615747

Work in progress: temporal energy hybrid subtraction in intravenous digital subtraction angiography
Journal Article · Fri Jul 01 00:00:00 EDT 1983 · Radiology; (United States) · OSTI ID:5819386