Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiation Exposure to Interventional Radiologists During Manual-Injection Digital Subtraction Angiography

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900252· OSTI ID:21080406
; ; ; ; ; ;  [1]
  1. Department of Radiology, Fukui Medical University School of Medicine, 23 Shimoaizuki, Matsuoka-cho, Yoshida-gun, Fukui 910-1193 (Japan)
Purpose: We investigated the relationship between the amount of radiation exposure to the operator during table-side manual-injection angiographic procedures including digital subtraction angiography (DSA) and the operator's position, as well as a simple means to decrease radiation exposure. Methods: Measurement of radiation exposure was carried out with thermoluminescent dosimeters (TLDs) in nine abdominal angiographies. In the first study, radiation exposure during DSA or during fluoroscopy was measured using TLDs placed near the angiographic table. In the second study, radiation exposure to the interventional radiologist was measured during manual-injection DSA at a near and a far operator position. Results: Radiation exposure to the operator received during manual-injection DSA accounted for more than 90% of the total procedural exposure. The exposure to the operator markedly decreased at the far position compared with that at the near position when performing DSA. Conclusion: Manual-injection DSA is the largest contributor to radiation exposure received by the interventional radiologist, therefore, the use of a power injector is always recommended when performing DSA. When manual-injection DSA is necessary, radiologists should position themselves as far away from the patient as possible.
OSTI ID:
21080406
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 3 Vol. 21; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Radiation exposure of personnel during digital subtraction angiography
Journal Article · Thu Mar 31 23:00:00 EST 1988 · Cardiovasc. Interv. Radiol.; (United States) · OSTI ID:6823499

Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Cardiovascular and Interventional Radiology · OSTI ID:22642501

Radiologist and angiographic procedures. Absorbed radiation dose
Journal Article · Tue Sep 01 00:00:00 EDT 1987 · Invest. Radiol.; (United States) · OSTI ID:5517486