Transbrachial Selective Pulmonary Angiography Using a New 4 Fr Curved Pigtail Catheter and Hydrophilic-Coated Guidewire
Journal Article
·
· Cardiovascular and Interventional Radiology
- Department of Radiology, National Defense Medical College, 3-2, Namiki, Tokorozawa-city, Saitama Prefecture 359 (Japan)
- Department of Radiology, School of Medicine, Tokai University, Bouseidai, Isehara-city, Kanagawa Prefecture 259-11 (Japan)
- Second Department of Surgery, National Defense Medical College, 3-2, Namiki, Tokorozawa-city, Saitama Prefecture 359 (Japan)
- Department of Diagnostic Radiology, School of Medicine, Keio University, 35 Shinanomachi, Shinjuku-ku, Tokyo 160 (Japan)
We have employed a new 4 Fr curved pigtail catheter with a hydrophilic-coated guidewire for transbrachial, selective pulmonary angiography using digital subtraction imaging. Eighteen patients and 27 pulmonary arteries were catheterized and selective pulmonary digital subtraction angiography was performed. Clinical diagnosis included lung cancer in 14 patients, thymoma in 1, bronchogenic cyst in 1, and pulmonary embolism in 2. Selective pulmonary arteriograms were obtained in all patients. No catheter-related complication occurred, although occasional premature ventricular contractions were noted. The high-flow injection rate of the contrast material resulted in clear visualization of the pulmonary arteries in all cases. This newly developed pigtail catheter combined with a hydrophilic-coated guidewire allowed easier and exact transbrachial selective pulmonary angiography to be performed. This technique does not require bedrest after the procedure and thus can be used in outpatients. It can also be used in patients who have thrombi along the transfemoral route.
- OSTI ID:
- 21080387
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 4 Vol. 21; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
The role of transradial diagnostic angiography
Digital subtraction pulmonary angiography
Migrated Hickman Catheters: A Simple Repositioning Method Using a Stiff Hydrophilic Guidewire
Journal Article
·
Fri Mar 14 23:00:00 EST 1997
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080237
Digital subtraction pulmonary angiography
Journal Article
·
Sun Aug 01 00:00:00 EDT 1982
· AJR, Am. J. Roentgenol.; (United States)
·
OSTI ID:6717509
Migrated Hickman Catheters: A Simple Repositioning Method Using a Stiff Hydrophilic Guidewire
Journal Article
·
Fri Jan 14 23:00:00 EST 2000
· Cardiovascular and Interventional Radiology
·
OSTI ID:21083686