Single and Tandem Stents in Sheep Iliac Arteries: Is There a Difference in Patency?
Journal Article
·
· Cardiovascular and Interventional Radiology
- Department of Diagnostic Radiology, University of Technology, Pauwelsstrasse 30, D-52057 Aachen (Germany)
Purpose: To compare patency and neointima formation of single and tandem arterial stents. Methods: In each of six sheep, two Memotherm nitinol stents (tandem stents) were inserted into the external iliac artery on one side and a single stent into the artery on the opposite side. The size of the iliac lumen was assessed in the proximal, middle, and distal segments of the stents by intravascular ultrasound (IVUS) before, immediately after, and 1 month after implantation when the sheep were killed. Neointimal thickness was determined in the proximal, middle, and distal segments of each stent by light microscopy. Results: All stents remained patent. There was no significant difference in lumen and neointimal thickness between single and tandem stents. Cranial tandem stents showed a significantly wider lumen and smaller neointimal thickness than caudal tandem stents. In the proximal and distal segments, the lumen of the stents was significantly smaller and the neointimal thickness greater than in the middle segment; differences in neointimal thickness were significant only between the proximal and the middle segment. Conclusion: In an experimental setting, tandem stents did not interfere with one another with regard to patency and neointima formation when compared with a single contralateral stent. Neointimal thickening after stent insertion seems to be inversely related to the original arterial diameter.
- OSTI ID:
- 21080374
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 5 Vol. 21; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Magnetic Resonance Angiography of Nonferromagnetic Iliac Artery Stents and Stent-Grafts: A Comparative Study in Sheep
Neointimal Hyperplasia in Low-Profile Nitinol Stents, Palmaz Stents, and Wallstents: A Comparative Experimental Study
Determination of Stent Stenosis: An In Vivo Experimental Comparison of Intravascular Ultrasound and Angiography with Histology
Journal Article
·
Wed Sep 15 00:00:00 EDT 1999
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080275
Neointimal Hyperplasia in Low-Profile Nitinol Stents, Palmaz Stents, and Wallstents: A Comparative Experimental Study
Journal Article
·
Mon Apr 15 00:00:00 EDT 1996
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080520
Determination of Stent Stenosis: An In Vivo Experimental Comparison of Intravascular Ultrasound and Angiography with Histology
Journal Article
·
Fri May 15 00:00:00 EDT 1998
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080411