Title: Nasolacrimal Polyurethane Stent: Complications with CT Correlation

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900302· OSTI ID:21080362
; ;  [1]
  1. Department of Radiology, Hospital Universitario de Getafe, Ctra. de Toledo, km 12.5, E-28905 Getafe, Madrid (Spain)

Purpose: To evaluate initial results in patients with epiphora secondary to obstruction of the nasolacrimal duct treated by placement of a polyurethane stent, and to discuss the technical problems and complications arising during the procedure, with visualization of the anatomy of the drainage apparatus using computed tomography (CT). Methods: We inserted 20 polyurethane Song stents under fluoroscopic guidance after dacryocystography in 19 patients with grade 3-4 epiphora caused by idiopathic obstruction of the nasolacrimal duct. CT scans were obtained following stent placement in all patients. Results: We focus on the technical problems and complications that arose during these procedures. During negotiation of the guidewire past the obstruction at the level of the junction of the duct with the lacrimal sac, the guidewire created a false passage in a posterior suborbital direction in two cases and towards the posterior midline in another. In all cases the guidewire was withdrawn and reinserted through the proper anatomic route without further difficulty or complications. In two cases the stent was improperly positioned wholly or partially outside the nasolacrimal system (one medially, one posteriorly). In one case the stent was removed and reinserted; in the other it remains in place and functional. CT was performed in all these cases to ensure proper anatomic alignment and determine what had gone wrong. The epiphora was completely resolved in 13 cases and partially relieved in four; there were three cases of stent obstruction. Epistaxis of short duration (1 hr) occurred in seven patients and headache in one. Conclusions: Treatment of epiphora with polyurethane stents is a technique that is well tolerated by patients and achieves a high success rate, yet problems in placement may be encountered. Though no major consequences for patients are involved, cognizance of such difficulties is important to avoid incorrect positioning of stents.

OSTI ID:
21080362
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 21, Issue 6; Other Information: DOI: 10.1007/s002709900302; Copyright (c) 1998 Springer-Verlag New York Inc; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Treatment of Complete and Partial Obstruction of the Nasolacrimal System with Polyurethane Stents: Initial Experience
Journal Article · Thu Jan 15 00:00:00 EST 1998 · Cardiovascular and Interventional Radiology · OSTI ID:21080362

Nasolacrimal Stenting: Toward Improving Outcomes with a Simple Modification of the Song Stent
Journal Article · Tue Aug 15 00:00:00 EDT 2006 · Cardiovascular and Interventional Radiology · OSTI ID:21080362

Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits
Journal Article · Sun Oct 15 00:00:00 EDT 2006 · Cardiovascular and Interventional Radiology · OSTI ID:21080362