Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Duplex Ultrasonography in Assessing Restenosis of Renal Artery Stents

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900435· OSTI ID:21080260
 [1];  [2];  [1];  [3];  [1]
  1. Department of Radiology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)
  2. Department of Nephrology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)
  3. Department of Radiology, University of Virginia Health Sciences Center, Charlottesville, VA 22908 (United States)
Purpose: To determine the accuracy and optimal threshold values of duplex ultrasonography (US) in assessing restenosis of renal artery stents. Methods: Twenty-four consecutive patients with 33 renal arteries that had previously been treated with placement of a Palmaz stent underwent duplex US prior to intraarterial digital subtraction angiography (DSA), which was the reference standard. Diagnostic accuracy of in-stent peak systolic velocity (PSV) and reno-aortic ratio (RAR = PSV renal stent/PSV aorta) in detecting > 50% in-stent restenosis were evaluated by the receiver operating characteristic curve. Sensitivity and specificity were determined using the optimal threshold values, and using published threshold values: RAR > 3.5 and in-stent PSV > 180 cm/sec. Results: Six examinations were technically inadequate. Nine stents had residual or restenosis > 50% at DSA. The two duplex parameters were equally accurate since areas under the curves were similar (0.943). With optimal threshold values of 226 cm/sec for PSV and 2.7 for RAR, sensitivities and specificities were 100% and 90%, and 100% and 84%, respectively. Using the published duplex criteria resulted in sensitivities and specificities of 100% and 74% for PSV, and 50% and 89% for RAR. Conclusion: Duplex US is a sensitive modality for detecting in-stent restenosis if laboratory-specific threshold values are used.
OSTI ID:
21080260
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 6 Vol. 22; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

The Erasme Study: A Multicenter Study on the Safety and Technical Results of the Palmaz Stent Used for the Treatment of Atherosclerotic Ostial Renal Artery Stenosis
Journal Article · Sun Nov 14 23:00:00 EST 1999 · Cardiovascular and Interventional Radiology · OSTI ID:21080262

Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis
Journal Article · Fri Apr 15 00:00:00 EDT 2005 · Cardiovascular and Interventional Radiology · OSTI ID:21088128

Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography
Journal Article · Wed Jan 14 23:00:00 EST 2004 · Cardiovascular and Interventional Radiology · OSTI ID:21088316