skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Fixed Gap APPLE II Undulator for SLS

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2436084· OSTI ID:21052538
; ; ; ;  [1]
  1. Paul Scherrer Institut, Swiss Light Source, 5232 Villigen PSI (Switzerland)

To vary the polarization vector of an APPLE II undulator continuously from 0 - 180 deg., all four magnet arrays need to be movable. Following the adjustable-phase undulator approach by R. Carr, a 3.4 m long fixed gap undulator for SLS with a gap of 11.6 mm has been constructed. It will be installed in fall 2006. The gap drive is replaced by a pair-wise shift of the magnet arrays to change the energy, while the polarization is changed by shifts of diagonal arrays. The high injection efficiency and standard operation top-up mode at the SLS allows this simplified undulator design. The design as well as the operational aspects will be discussed.

OSTI ID:
21052538
Journal Information:
AIP Conference Proceedings, Vol. 879, Issue 1; Conference: 9. international conference on synchrotron radiation instrumentation, Daegu (Korea, Republic of), 28 May - 2 Jun 2006; Other Information: DOI: 10.1063/1.2436084; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

About APPLE II Operation
Journal Article · Fri Jan 19 00:00:00 EST 2007 · AIP Conference Proceedings · OSTI ID:21052538

Performance of Small-Gap Undulators at the SLS Intermediate Energy Storage Ring
Journal Article · Fri Jan 19 00:00:00 EST 2007 · AIP Conference Proceedings · OSTI ID:21052538

Characterization of the Support and Drive System of the PETRA III APPLE Undulator
Journal Article · Wed Jun 23 00:00:00 EDT 2010 · AIP Conference Proceedings · OSTI ID:21052538