Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Investigation of Accelerated Partial Breast Patient Alignment and Treatment With Helical Tomotherapy Unit

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
; ; ; ; ;  [1]; ; ;  [2];  [2]
  1. Department of Radiation Oncology, M. D. Anderson Cancer Center Orlando, Orlando, FL (United States)
  2. TomoTherapy, Incorporated, Madison, WI (United States)
Purpose: To determine the precision of megavoltage computed tomography (MVCT)-based alignment of the seroma cavity for patients undergoing partial breast irradiation; and to determine whether accelerated partial breast irradiation (APBI) plans can be generated for TomoTherapy deliveries that meet the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol guidelines for target coverage and normal tissue dose limitations. Methods and Materials: We obtained 50 MVCT images from 10 patients. An interuser study was designed to assess the alignment precision. Using a standard helical and a fixed beam prototype ('topotherapy') optimizer, two APBI plans for each patient were developed. Results: The precision of the MVCT-based seroma cavity alignment was better than 2 mm if averaged over the patient population. Both treatment techniques could be used to generate acceptable APBI plans for patients that fulfilled the recommended NSABP B-39/RTOG-0413 selection criteria. For plans of comparable treatment time, the conformation of the prescription dose to the target was greater for helical deliveries, while the ipsilateral lung dose was significantly reduced for the topotherapy plans. Conclusions: The inherent volumetric imaging capabilities of a TomoTherapy Hi-Art unit allow for alignment of patients undergoing partial breast irradiation that is determined from the visibility of the seroma cavity on the MVCT image. The precision of the MVCT-based alignment was better than 2 mm ({+-} standard deviation) when averaged over the patient population. Using the NSABP B-39/RTOG-0413 guidelines, acceptable APBI treatment plans can be generated using helical- or topotherapy-based delivery techniques.
OSTI ID:
21039853
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 4 Vol. 70; ISSN IOBPD3; ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients
Journal Article · Fri May 01 00:00:00 EDT 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21276799

Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy
Journal Article · Thu Feb 14 23:00:00 EST 2013 · Medical Physics · OSTI ID:22130519

Dose-modeling study to compare external beam techniques from protocol NSABP B-39/RTOG 0413 for patients with highly unfavorable cardiac anatomy
Journal Article · Tue Aug 01 00:00:00 EDT 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20850016