On-Line Target Position Localization in the Presence of Respiration: A Comparison of two Methods
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)
Purpose: To compare two 'four-dimensional' methods for image-guided target localization in the presence of respiration. Methods and Materials: Four-dimensional image guidance was performed with two methods. A respiration-correlated computed tomography (RCCT) was acquired on a CT simulator, and an average CT (AVG-CT) image was generated from the RCCT. A respiration-correlated cone-beam CT (RC-CBCT) and a free-breathing cone-beam CT (FB-CBCT) were acquired. The 'RCCT method' consisted of calculating the mean target position on both the RCCT and RC-CBCT, registering the RCCT to the RC-CBCT, and determining the shift in the mean target position from the planned mean position. The 'AVG-CT method' consisted of registering the AVG-CT to the FB-CBCT. The ability of each to measure the shift in the mean target position was compared, both in a respiratory phantom and in 8 patients. Results: In phantom, the RCCT and AVG-CT methods were able to measure the true mean target position to within 0.15 cm and 0.10 cm, respectively. In the patient study, the mean error between the methods was 0.13 cm (left-right), 0.14 cm (anterior-posterior), and 0.10 cm (cranio-caudal). The error was not observed to vary with tumor position or magnitude of tumor motion. Conclusions: Respiration may impact the on-line image guidance process. The RCCT method enables localization of the mean tumor position and measurement of changes in the motion pattern, whereas the AVG-CT method is simple, fast, and easily implemented. We found the methods to be nearly equivalent in detecting shifts in the mean tumor position.
- OSTI ID:
- 21039691
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 5 Vol. 69; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison of setup error using different reference images: a phantom and lung cancer patients study
A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer
Evaluation of tumor localization in respiration motion-corrected cone-beam CT: Prospective study in lung
Journal Article
·
Sun Apr 01 00:00:00 EDT 2012
· Medical Dosimetry
·
OSTI ID:22130378
A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer
Journal Article
·
Mon Oct 15 00:00:00 EDT 2012
· Medical Physics
·
OSTI ID:22099024
Evaluation of tumor localization in respiration motion-corrected cone-beam CT: Prospective study in lung
Journal Article
·
Wed Oct 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22409491