Title: Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2799579· OSTI ID:21032871
; ; ; ; ; ;  [1]
  1. Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 and Drexel University College of Medicine, Allegheny Campus, Pittsburgh, Pennsylvania 15212 (United States)

A dosimetric comparison was performed on external-beam three-dimensional conformal partial breast irradiation (PBI) and whole breast irradiation (WBI) plans for patients enrolled in the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol at our institution. Twenty-four consecutive patients were treated with either PBI (12 patients) or WBI (12 patients). In the PBI arm, the lumpectomy cavity was treated to a total dose of 38.5 Gy at 3.85 Gy per fraction twice daily using a four-field noncoplanar beam setup. A minimum 6 h interval was required between fractions. In the WBI arm, the whole breast including the entirety of the lumpectomy cavity was treated to a total dose of 50.4 Gy at 1.8 Gy per fraction daily using opposed tangential beams. The lumpectomy cavity volume, planning target volume for evaluation (PTV{sub E}VAL), and critical structure volumes were contoured for both the PBI and WBI patients. Dosimetric parameters, dose volume histograms (DVHs), and generalized equivalent uniform dose (gEUD) for target and critical structures were compared. Dosimetric results show the PBI plans, compared to the WBI plans, have smaller hot spots in the PTV{sub E}VAL (maximum dose: 104.2% versus 110.9%) and reduced dose to the ipsilateral breast (V50: 48.6% versus 92.1% and V100: 10.2% versus 50.5%), contralateral breast (V3: 0.16% versus 2.04%), ipsilateral lung (V30: 5.8% versus 12.7%), and thyroid (maximum dose: 0.5% versus 2.0%) with p values {<=}0.01. However, similar dose coverage of the PTV{sub E}VAL (98% for PBI and 99% for WBI, on average) was observed and the dose difference for other critical structures was clinically insignificant in both arms. The gEUD data analysis showed the reduction of dose to the ipsilateral breast and lung, contralateral breast and thyroid. In addition, preliminary dermatologic adverse event assessment data suggested reduced skin toxicity for patients treated with the PBI technique.

OSTI ID:
21032871
Journal Information:
Medical Physics, Vol. 34, Issue 12; Other Information: DOI: 10.1118/1.2799579; (c) 2007 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Prone Accelerated Partial Breast Irradiation After Breast-Conserving Surgery: Compliance to the Dosimetry Requirements of RTOG-0413
Journal Article · Thu Nov 15 00:00:00 EST 2012 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21032871

Accelerated partial breast irradiation using proton beams: Initial dosimetric experience
Journal Article · Tue Aug 01 00:00:00 EDT 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21032871

SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:21032871