Joint model of motion and anatomy for PET image reconstruction

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2804721· OSTI ID:21032870
; ; ;  [1]
  1. Electrical and Computer Engineering Department, Rice University, 6100 Main St. MS-366, Houston, Texas 77005 (United States)

Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respiratory motion. In this article, we present a joint model of both motion and anatomical information by integrating a motion-incorporated PET imaging system model with an anatomy-based maximum a posteriori image reconstruction algorithm. The mismatched anatomical information due to motion can thus be effectively utilized through this joint model. A computer simulation and a phantom study were conducted to assess the efficacy of the joint model, whereby motion and anatomical information were either modeled separately or combined. The reconstructed images in each case were compared to corresponding reference images obtained using a quadratic image prior based maximum a posteriori reconstruction algorithm for quantitative accuracy. Results of these studies indicated that while modeling anatomical information or motion alone improved the PET image quantitation accuracy, a larger improvement in accuracy was achieved when using the joint model. In the computer simulation study and using similar image noise levels, the improvement in quantitation accuracy compared to the reference images was 5.3% and 19.8% when using anatomical or motion information alone, respectively, and 35.5% when using the joint model. In the phantom study, these results were 5.6%, 5.8%, and 19.8%, respectively. These results suggest that motion compensation is important in order to effectively utilize anatomical information in chest imaging using PET. The joint motion-anatomy model presented in this paper provides a promising solution to this problem.

OSTI ID:
21032870
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 12 Vol. 34; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Conference · Wed Nov 30 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6705193

Bayesian reconstruction of functional images using anatomical information as priors
Journal Article · Tue Nov 30 23:00:00 EST 1993 · IEEE Transactions on Medical Imaging (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5043048

Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
Journal Article · Mon Apr 15 00:00:00 EDT 2013 · Medical Physics · OSTI ID:22130604