Study of the Load Resilient External Matching Circuit for the ITER ICRH/FWCD System by means of its Mock-up

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2800467· OSTI ID:21032749
; ; ;  [1]
  1. Plasma Physics Laboratory, Association EURATOM--Belgian State, Partner in TEC, Royal Military Academy, Brussels (Belgium)
The reference matching solution for ITER grouping the 24 straps of the ITER antenna array in 4 'conjugate T' (CT) circuits through pre-matching network is investigated starting from the S matrix measurements versus antenna loading made on the mock-up of the original design. Six decouplers alleviate the mutual coupling effects between the 4 matching circuits and their power sources. All matching actuators are outside the antenna plug. The matching procedure allows the control of load resilience and plasma excitation spectrum for heating and current drive.
OSTI ID:
21032749
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 933; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Study of the ITER ICRH system with external matching by means of a mock-up loaded by a variable water load
Journal Article · Mon Sep 26 00:00:00 EDT 2005 · AIP Conference Proceedings · OSTI ID:20726308

Experimental proof of a load resilient external matching solution for the ITER ICRH system
Journal Article · Mon Sep 26 00:00:00 EDT 2005 · AIP Conference Proceedings · OSTI ID:20726309

Results of the implementation on a mock-up of the full 3dB hybrid matching option of the ITER ICRH system
Journal Article · Thu Dec 22 23:00:00 EST 2011 · AIP Conference Proceedings · OSTI ID:21612507