Acoustic Analysis for a Steam Dome and Pipings of a 1,100 MWe-Class Boiling Water Reactor
Conference
·
OSTI ID:21021144
- Power and Industrial Systems Research and Development Center, Toshiba Corporation 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8523 (Japan)
For the integrity evaluation of steam dryers in up-rated nuclear power plants, we have applied acoustic analysis to a nuclear power plant steam dome and main steam pipings. We have selected a 1,100 MWe-class boiling water reactor as a subject of the analysis. We have constructed a three-dimensional finite element model, and conducted acoustic analyses. The analysis result suggested that the origin of steam pressure pulsation in high frequency range was due to vortex shedding at standpipes. (authors)
- Research Organization:
- American Nuclear Society, 555 North Kensington Avenue, La Grange Park, IL 60526 (United States)
- OSTI ID:
- 21021144
- Country of Publication:
- United States
- Language:
- English
Similar Records
Quad Cities Unit 2 Main Steam Line Acoustic Source Identification and Load Reduction
Study on acoustic resonance and its damping of BWR steam dome
300 MWe MULTIPLE BOILING SATURATED AND SUPERHEAT STEAM REACTOR PLANT STUDY