Application of USNRC NUREG/CR-6661 and draft DG-1108 to evolutionary and advanced reactor designs
Conference
·
OSTI ID:21021089
- Apollo Consulting, Inc., Surprise, AZ 85374-4605 (United States)
For the seismic design of evolutionary and advanced nuclear reactor power plants, there are definite financial advantages in the application of USNRC NUREG/CR-6661 and draft Regulatory Guide DG-1108. NUREG/CR-6661, 'Benchmark Program for the Evaluation of Methods to Analyze Non-Classically Damped Coupled Systems', was by Brookhaven National Laboratory (BNL) for the USNRC, and Draft Regulatory Guide DG-1108 is the proposed revision to the current Regulatory Guide (RG) 1.92, Revision 1, 'Combining Modal Responses and Spatial Components in Seismic Response Analysis'. The draft Regulatory Guide DG-1108 is available at http://members.cox.net/apolloconsulting, which also provides a link to the USNRC ADAMS site to search for NUREG/CR-6661 in text file or image file. The draft Regulatory Guide DG-1108 removes unnecessary conservatism in the modal combinations for closely spaced modes in seismic response spectrum analysis. Its application will be very helpful in coupled seismic analysis for structures and heavy equipment to reduce seismic responses and in piping system seismic design. In the NUREG/CR-6661 benchmark program, which investigated coupled seismic analysis of structures and equipment or piping systems with different damping values, three of the four participants applied the complex mode solution method to handle different damping values for structures, equipment, and piping systems. The fourth participant applied the classical normal mode method with equivalent weighted damping values to handle differences in structural, equipment, and piping system damping values. Coupled analysis will reduce the equipment responses when equipment, or piping system and structure are in or close to resonance. However, this reduction in responses occurs only if the realistic DG-1108 modal response combination method is applied, because closely spaced modes will be produced when structure and equipment or piping systems are in or close to resonance. Otherwise, the conservatism in the current Regulatory Guide 1.92, Revision 1, will overshadow the advantage of coupled analysis. All four participants applied the realistic modal combination method of DG-1108. Consequently, more realistic and reduced responses were obtained. (authors)
- Research Organization:
- American Nuclear Society, 555 North Kensington Avenue, La Grange Park, IL 60526 (United States)
- OSTI ID:
- 21021089
- Country of Publication:
- United States
- Language:
- English
Similar Records
INEL/USNRC pipe damping experiments and studies
Dynamic analysis techniques--a sensitivity study for piping systems at a nuclear power plant
A BENCHMARK PROGRAM FOR EVALUATION OF METHODS FOR COMPUTING SEISMIC RESPONSE OF COUPLED BUILDING-PIPING/EQUIPMENT WITH NON-CLASSICAL DAMPING.
Conference
·
Sat Aug 01 00:00:00 EDT 1987
·
OSTI ID:6304145
Dynamic analysis techniques--a sensitivity study for piping systems at a nuclear power plant
Journal Article
·
Wed Dec 31 23:00:00 EST 1980
· HTD (Publ.) (Am. Soc. Mech. Eng.); (United States)
·
OSTI ID:5487445
A BENCHMARK PROGRAM FOR EVALUATION OF METHODS FOR COMPUTING SEISMIC RESPONSE OF COUPLED BUILDING-PIPING/EQUIPMENT WITH NON-CLASSICAL DAMPING.
Conference
·
Wed Mar 21 23:00:00 EST 2001
·
OSTI ID:779781