Trilateral optical powermeter comparison between NIST, NMIJ/AIST, and METAS
We describe the results of a comparison of reference standards between three National Metrology Institutes: the National Institute of Standards and Technology (NIST, USA),the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology (NMIJ/AIST, Japan), and the Federal Office of Metrology (METAS, Switzerland).Open-beam- (free field) and optical-fiber-based measurements at wavelengths of 1302 and1546 nmare reported. Three laboratories' reference standards are compared by means of two temperature-controlled, optical trap detectors. Measurement results show the largest differences of less than 4.2 parts in 103, which is within the expanded(k=2) uncertainty for the laboratories'reference standards.
- OSTI ID:
- 20929600
- Journal Information:
- Applied Optics, Vol. 46, Issue 5; Other Information: DOI: 10.1364/AO.46.000643; (c) 2007 Optical Society of America; Country of input: International Atomic Energy Agency (IAEA); ISSN 0003-6935
- Country of Publication:
- United States
- Language:
- English
Similar Records
Realizations of the ITS-90 below 24.5561 K at NMIJ/AIST
Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers