skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Linear signal-compensated amplifier for reactor power measuring channels

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2219752· OSTI ID:20853365
; ;  [1]
  1. Electronics Division, PINSTECH, Islamabad 44000 (Pakistan)

A linear amplifier with automatic signal compensation has been developed for nuclear channels. The amplifier controls its sensitivity automatically according to the reference input within the desired settings and has automatic signal compensation capability for use in the nuclear channels. The amplifier will be used in the existing safety channel of Pakistan Research Reactor-1, where the system has an independent sensitivity control unit for manual compensation of xenon effect. The new amplifier will improve the safety of the system. The amplifier is tested and the results found are in very good agreement with the designed specifications. This article presents design and construction of the amplifier and test results.

OSTI ID:
20853365
Journal Information:
Review of Scientific Instruments, Vol. 77, Issue 7; Other Information: DOI: 10.1063/1.2219752; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English