Title: Compact radiometric microwave calibrator

Abstract

The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency.

Authors:
; ; ; ; ; ;  [1];  [2];  [2];  [2];  [2]
  1. SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771 (United States)
  2. (United States)
Publication Date:
OSTI Identifier:
20853300
Resource Type:
Journal Article
Resource Relation:
Journal Name: Review of Scientific Instruments; Journal Volume: 77; Journal Issue: 6; Other Information: DOI: 10.1063/1.2209960; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ACCURACY; ALUMINIUM; ANTENNAS; CALIBRATION; CONES; MICROWAVE RADIATION; RADIOMETERS; REFLECTION; WAVELENGTHS

Citation Formats

Fixsen, D. J., Wollack, E. J., Kogut, A., Limon, M., Mirel, P., Singal, J., Fixsen, S. M., Code 665, Goddard Spaceflight Center, Greenbelt, Maryland 20771, SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771, University of California Santa Barbara, Santa Barbara, California 93106, and SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771. Compact radiometric microwave calibrator. United States: N. p., 2006. Web. doi:10.1063/1.2209960.
Fixsen, D. J., Wollack, E. J., Kogut, A., Limon, M., Mirel, P., Singal, J., Fixsen, S. M., Code 665, Goddard Spaceflight Center, Greenbelt, Maryland 20771, SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771, University of California Santa Barbara, Santa Barbara, California 93106, & SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771. Compact radiometric microwave calibrator. United States. doi:10.1063/1.2209960.
Fixsen, D. J., Wollack, E. J., Kogut, A., Limon, M., Mirel, P., Singal, J., Fixsen, S. M., Code 665, Goddard Spaceflight Center, Greenbelt, Maryland 20771, SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771, University of California Santa Barbara, Santa Barbara, California 93106, and SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771. Thu . "Compact radiometric microwave calibrator". United States. doi:10.1063/1.2209960.
@article{osti_20853300,
title = {Compact radiometric microwave calibrator},
author = {Fixsen, D. J. and Wollack, E. J. and Kogut, A. and Limon, M. and Mirel, P. and Singal, J. and Fixsen, S. M. and Code 665, Goddard Spaceflight Center, Greenbelt, Maryland 20771 and SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771 and University of California Santa Barbara, Santa Barbara, California 93106 and SSAI Goddard Spaceflight Center, Greenbelt, Maryland 20771},
abstractNote = {The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency.},
doi = {10.1063/1.2209960},
journal = {Review of Scientific Instruments},
number = 6,
volume = 77,
place = {United States},
year = {Thu Jun 15 00:00:00 EDT 2006},
month = {Thu Jun 15 00:00:00 EDT 2006}
}
  • This paper proposes a simplified microwave model, linearized by Taylor expansion and incorporating observed fundamental microwave emissive properties, and discusses its application along with the least square method for determining some oceanic environmental parametric values from multichannel observation data. As a case study, microwave radiometric observations were made in vertical and horizontal polarizations at 6.7 and 18.6 GHz at incidence angles from 20/sup 0/ to 70/sup 0/ at steps of 10/sup 0/, and sea-surface temperature, wind speed, and sky brightness temperatures at the above dual frequencies at zenith angles from 20/sup 0/ to 70/sup 0/ were determined from a setmore » of observed data at each incidence angle. The algorithm-derived results were compared with observed ones and showed good agreements within 10 percent of errors at incidence angles from 20/sup 0/ to 60/sup 0/; however, no good agreement was attained at large incidence angles such as 70/sup 0/, except sky brightness temperature at 6.7 GHz.« less
  • The transport equation for microwave energy in a large metal chamber is solved to find the plasma emissivity and the coefficient for the transport of microwave power from the plasma--chamber system to the input of a radiometric receiver. An experimental method is proposed for determining this transport coefficient (for calibrating the radiometer scale) using the microwaves emitted from a plasma in a metal chamber. The results found using this method to study the plasma in the Uragan 2 stellarator are reported.
  • An airborne microwave survey was made in the region of the San Joaquin nuclear project site near Bakersfield, Calif. The purpose of the study was to determine if the variability of soil emissivity due to moisture content is a valid near-surface expression of buried fault systems. The results showed the existence of linear-emissivity anomalies paralleling, and to some extent, overlying the Greeley and Pond-Poso Creek faults. The anomalies seem to be direct expressions of silt-filled, northwesterly trending channels of the Pond-Poso Creek-Tulare Lake distributary system. The location, orientation, and linearity of the distributary channels suggest an association with buried faults,more » but no relationship has yet been determined.« less
  • A microwave radiometer relies on the power linearity of its microwave receivers to accurately measure the temperature of remote microwave noise sources. This paper considers linearity issues in the design and characterization of such receivers. Analysis is presented relating the radiometer temperature interpolation error to a second order power nonlinearity coefficient for the receiver. Formulas are also developed specifying the temperature error in terms of individual receiver component parameters. It is shown that the key parameter for the RF detector in the receiver is A{sub 4}, a fourth order RF distortion coefficient, and the key parameter for the RF amplifiersmore » in the receiver is IP{sub 3}, the third order intercept. This paper also discusses experimental methods for measuring the power linearity of RF detectors to the levels required for radiometric applications. Three methods are discussed: the two-tone method, the amplitude modulation method, and the constant ratio method. The theory of determining the coefficients that characterize the nonlinearity of the detector from experimental data is presented. Experimental results are presented showing that the two-tone method and the constant ratio method agree to within experimental error. The sensitivity for measuring nonlinearities and the difficulties encountered in implementing each of these methods are also discussed.« less