skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Application of the electron pencil beam redefinition algorithm to electron arc therapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2207215· OSTI ID:20853211
; ; ; ; ;  [1]
  1. Departments of Radiation Physics and Biostatistics and Applied Math, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Medical Physics Program, The University of Texas Graduate School of Biomedical Sciences, Houston, Texas 77030 (United States)

This project investigated the potential of summing fixed-beam dose distributions calculated using the pencil-beam redefinition algorithm (PBRA) at small angular steps (1 deg.) to model an electron arc therapy beam. The PRBA, previously modified to model skin collimation, was modified further by incorporating two correction factors. One correction factor that is energy, SSD (source-to-surface distance), and field-width dependent constrained the calculated dose output to be the same as the measured dose output for fixed-beam geometries within the range of field widths and SSDs encountered in arc therapy. Another correction factor (single field-width correction factor for each energy) compensated for large-angle scattering not being modeled, allowing a more accurate calculation of dose output at mid arc. The PBRA was commissioned to accurately calculate dose in a water phantom for fixed-beam geometries typical of electron arc therapy. Calculated central-axis depth doses agreed with measured doses to within 2% in the low-dose gradient regions and within 1-mm in the high-dose gradient regions. Off-axis doses agreed to within 2 mm in the high-dose gradient regions and within 3% in the low-dose gradient regions. Arced-beam calculations of dose output and depth dose at mid arc were evaluated by comparing to data measured using two cylindrical water phantoms with radii of 12 and 15 cm at 10 and 15 MeV. Dose output was measured for all combinations of phantom radii of curvature, collimator widths (4, 5, and 6 cm), and arc angles (0 deg., 20 deg., 40 deg., 60 deg., 80 deg., and 90 deg.) for both beam energies. Results showed the calculated mid-arc dose output to agree within 2% of measurement for all combinations. For a 90 deg.arc angle and 5x20 cm{sup 2} field size, the calculated mid-arc depth dose in the low-dose gradient region agreed to within 2% of measurement for all depths at 10 MeV and for depths greater than depth of dose maximum R{sub 100} at 15 MeV. For depths in the buildup region at 15 MeV the calculations overestimated the measured dose by as much as 3.4%. Mid-arc depth dose in the high-dose gradient region agreed to within 2.2 mm of measured dose. Calculated two-dimensional relative dose distributions in the plane of rotation were compared to dose measurements using film in a cylindrical polystyrene phantom for a 90 deg.arc angle and field widths of 4, 5, and 6 cm at 10 and 15 MeV. Results showed that off-axis dose at the ends of arc (without skin collimation) agreed to within 2% in the low-dose gradient region and to within 1.2 mm in the high-dose gradient region. This work showed that the accuracy of the PBRA arced-beam dose model met the criteria specified by Van Dyk et al. [Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)] with the exception of the buildup region of the 15 MeV beam. Based on the present results, results of a previous study showing acceptable accuracy in the presence of skin collimation, and results of a previous study showing acceptable accuracy in the presence of internal heterogeneities, it is concluded that the PBRA arced-beam dose model should be adequate for planning electron arc therapy.

OSTI ID:
20853211
Journal Information:
Medical Physics, Vol. 33, Issue 7; Other Information: DOI: 10.1118/1.2207215; (c) 2006 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English