Diagnostics System of JT-60U
Journal Article
·
· Fusion Science and Technology
OSTI ID:20845866
The diagnostic system of JT-60U (JT-60upgrade) is composed of about 50 individual diagnostic devices. Recently, the detailed radial profile measurements of plasma parameters have been improved, so that the internal structure of plasmas could be explored. The understanding of plasma confinement has been enhanced by density and temperature fluctuation measurements using a mm-wave reflectometer and electron cyclotron emission measurements, respectively. In addition, real-time control experiments of electron density, neutron yield, radiated power, and electron temperature gradient have been carried out successfully by corresponding diagnostic devices. These measurements and the real-time control contribute to improving plasma performance. Diagnostic devices for next generation fusion devices such as a CO{sub 2} laser interferometer/polarimeter and a CO{sub 2} laser collective Thomson scattering system have been developed.
- OSTI ID:
- 20845866
- Journal Information:
- Fusion Science and Technology, Journal Name: Fusion Science and Technology Journal Issue: 2,3 Vol. 42; ISSN 1536-1055
- Country of Publication:
- United States
- Language:
- English
Similar Records
Quantitative method for precise, quick, and reliable alignment of collection object fields in the JT-60U Thomson scattering diagnostic
Disruption Studies in JT-60U
Toroidal interferometer/polarimeter density measurement system on ITER
Journal Article
·
Fri Jan 31 23:00:00 EST 1997
· Review of Scientific Instruments
·
OSTI ID:451078
Disruption Studies in JT-60U
Journal Article
·
Sun Sep 15 00:00:00 EDT 2002
· Fusion Science and Technology
·
OSTI ID:20845854
Toroidal interferometer/polarimeter density measurement system on ITER
Journal Article
·
Fri Oct 01 00:00:00 EDT 2004
· Review of Scientific Instruments
·
OSTI ID:20636642