Influence of the Pipe Diameter on the Structure of the Gas-Liquid Interface in a Vertical Two-Phase Pipe Flow
- Forschungszentrum Rossendorf (Germany)
Air-water two-phase flow tests in a large vertical pipe of 194.1-mm inner diameter (i.d.) are reported. Close to the outlet of a 9-m-tall test section, two wire-mesh sensors are installed that deliver instantaneous void fraction distributions over the entire cross section with a resolution of 3 mm and 2500 Hz used for fast-flow visualization. Void fraction profiles, gas velocity profiles, and bubble-size distributions were obtained. A comparison to a small pipe of 52.3-mm i.d. (DN50) revealed significant scaling effects. Here, the increase of the airflow rate leads to a transition from bubbly via slug to churn-turbulent flow. This is accompanied by an appearance of a second peak in the bubble-size distribution. A similar behavior was found in the large pipe; though the large bubbles have a significantly larger diameter at identical superficial velocities, the peak is less high but wider. These bubbles move more freely in the large pipe and show more deformations. The shapes of such large bubbles were characterized in three dimensions. They can be rather complicated and far from ideal Taylor bubbles. Also, the small bubble fraction tends to bigger sizes in the large pipe.
- OSTI ID:
- 20840308
- Journal Information:
- Nuclear Technology, Journal Name: Nuclear Technology Journal Issue: 1 Vol. 152; ISSN 0029-5450; ISSN NUTYBB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures
Predicting multiphase flow behavior in a deviated well