Measuring high-energy {gamma} rays with Ge detectors
Journal Article
·
· AIP Conference Proceedings
- J. Stefan Institute, 1000 Ljubljana (Slovenia)
- iThemba LABS, 7129 Somerset West (South Africa)
Gamma rays with energies up to 21 MeV were measured with Ge detectors. Such {gamma} rays were produced in the 208Pb(p,{gamma})209Bi reaction. The position of the 2g9/2 single proton orbit in 209Bi has been determined indicating the size of the Z=126 shell gap.