Natural Crack Sizing Based on Eddy Current Image and Electromagnetic Field Analyses

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2184598· OSTI ID:20798264
; ;  [1]; ; ;  [2]
  1. Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai (Japan)
  2. Power and Industrial Systems, R and D Laboratory, Hitachi, Ltd., Hitachi, Ibaraki (Japan)
An eddy current testing (ECT) system with multi-coil type probes is applied to size up cracks fabricated on austenite stainless plates. We have developed muti-channel ECT system to produce data as digital images. The probes consist of transmit-receive type sensors as elements to classify crack directions, working as two scan direction modes simultaneously. Template matching applied to the ECT images determines regions of interest in sizing up cracks. Finite element based inversion sizes up the crack depth from the measured ECT signal. The present paper demonstrates this approach for fatigue crack and stress corrosion cracking.
OSTI ID:
20798264
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 820; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Eddy Current Testing and Sizing of Deep Cracks in a Thick Structure
Journal Article · Wed Feb 25 23:00:00 EST 2004 · AIP Conference Proceedings · OSTI ID:20632927

Development of the Non-Destructive Evaluation System Using an Eddy Current Probe for Detection of Fatigue Damage in a Stainless Steel
Journal Article · Sun Mar 05 23:00:00 EST 2006 · AIP Conference Proceedings · OSTI ID:20798252

Transmit-receive eddy current probes for defect detection and sizing in steam generator tubes
Conference · Fri Jan 31 23:00:00 EST 1997 · OSTI ID:467901