Title: Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [1];  [2];  [3];  [2];  [2];  [4];  [5];  [6];  [6];  [7];  [6]
  1. Department of Radiation Oncology, M.D. Anderson Cancer Center Orlando, Orlando, FL (United States)
  2. Department of Radiation Oncology, University of California, San Francisco, CA (United States)
  3. Department of Urology, University of California, San Francisco, CA (United States)
  4. Calypso Medical Technologies, Seattle, WA (United States)
  5. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USADepartment of (United States)
  6. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States)
  7. Department of Urology, University of Michigan, Ann Arbor, MI (United States)

Purpose: The Calypso 4D Localization System is being developed to provide accurate, precise, objective, and continuous target localization during radiotherapy. This study involves the first human use of the system, to evaluate the localization accuracy of this technique compared with radiographic localization and to assess its ability to obtain real-time prostate-motion information. Methods and Materials: Three transponders were implanted in each of 20 patients. Eleven eligible patients of the 20 patients participated in a study arm that compared radiographic triangulated transponder locations to electromagnetically recorded transponder locations. Transponders were tracked for 8-min periods. Results: The implantations were all successful, with no major complications. Intertransponder distances were largely stable. Comparison of the patient localization on the basis of transponder locations as per the Calypso system with the radiographic transponder localization showed an average ({+-}SD) 3D difference of 1.5 {+-} 0.9 mm. Upon tracking during 8 min, 2 of the 11 patients showed significant organ motion (>1 cm), with some motion lasting longer that 1 min. Conclusion: Calypso transponders can be used as magnetic intraprostatic fiducials. Clinical evaluation of this novel 4D nonionizing electromagnetic localization system with transponders indicates a comparable localization accuracy to isocenter (within 2 mm) compared with X-ray localiza0010ti.

OSTI ID:
20793514
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 65, Issue 2; Other Information: DOI: 10.1016/j.ijrobp.2006.01.050; PII: S0360-3016(06)00253-7; Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Fiducial-Based Translational Localization Accuracy of Electromagnetic Tracking System and On-Board Kilovoltage Imaging System
Journal Article · Sat Mar 01 00:00:00 EST 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20793514

Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
Journal Article · Thu Mar 15 00:00:00 EDT 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20793514

Daily Isocenter Correction With Electromagnetic-Based Localization Improves Target Coverage and Rectal Sparing During Prostate Radiotherapy
Journal Article · Mon Mar 15 00:00:00 EDT 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20793514