skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Characteristics of long-pulse negative-ion source in the neutral beam injector of Large Helical Device

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2166675· OSTI ID:20779008

The injection duration has been extended beyond 100 s with a high-power hydrogen negative-ion source in a negative-ion-based neutral beam injector of the Large Helical Device superconducting fusion machine. The ion source is a cesium-seeded source with a thermally insulated plasma grid (PG), and optimized for a short-pulse operation of 2-3 s. The negative-ion production efficiency is strongly dependent on the PG temperature, and in the long-pulse operation it exceeds an appropriate temperature range of 200-300 deg. C, at which the optimum cesium coverage is formed on the PG surface. By making the PG temperature rise slower with a reduced arc power, the injection duration was extended to 110 s with an injection power of 110 kW. To extend the injection duration further with a higher injection power, stainless-steel cooling tubes have been mechanically attached to the PG for suppression of the PG temperature rise in the long-pulse operation. As a result, a long-pulse injection with an injection power of 200 kW was extended to 128 s until it was manually stopped due to the plasma collapse. However, the beam duration could be limited to around 3 min because the PG temperature rise was not saturated due to a low thermal conductivity with the thickness of the stainless-steel tube determined so that the short-pulse operation is also possible. On the other hand, the longitudinal beam distribution in a grid area of 25x125 cm{sup 2} is observed to be more uniform than that with the uncooled PG. The temperature distribution of the individual grid parts becomes more uniform with the cooled PG, which should contribute to the improvement of the beam uniformity.

OSTI ID:
20779008
Journal Information:
Review of Scientific Instruments, Vol. 77, Issue 3; Conference: 11. international conference on ion sources, Caen (France), 12-16 Sep 2005; Other Information: DOI: 10.1063/1.2166675; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Long-pulse operation of a cesium-seeded high-current large negative ion source
Journal Article · Thu May 01 00:00:00 EDT 1997 · Review of Scientific Instruments · OSTI ID:20779008

Actively cooled plasma electrode for long pulse operations in a cesium-seeded negative ion source
Journal Article · Sat Jan 01 00:00:00 EST 2005 · Review of Scientific Instruments · OSTI ID:20779008

High-Power Negative Ion Sources for Neutral Beam Injectors in Large Helical Device
Journal Article · Fri Aug 10 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:20779008