Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Effect of the plasma electrode position and shape on the beam intensity of the highly charged ions from RIKEN 18 GHz electron-cyclotron-resonance ion source

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2171671· OSTI ID:20778969

Beam intensities of highly charged Ar ions (Ar{sup 11+,12+}) were measured as a function of plasma electrode position. We observed that the beam intensity of Ar{sup 11+,12+} increased when putting the electrode far from the electron-cyclotron-resonance zone. On the other hand, lower charged heavy ions (Ar{sup 8+,7+}) dramatically decreased. We observed that the intense beam extraction strongly affects the plasma condition. It may be due to the ion pumping effect.

OSTI ID:
20778969
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 3 Vol. 77; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Effect of the plasma electrode position on the beam intensity and emittance of the RIKEN 18 GHz ECRIS
Journal Article · Mon Mar 14 23:00:00 EST 2005 · AIP Conference Proceedings · OSTI ID:20630696

Production of highly charged heavy ions by 18 GHz superconducting electron cyclotron resonance at Research Center for Nuclear Physics
Journal Article · Sun Feb 14 23:00:00 EST 2010 · Review of Scientific Instruments · OSTI ID:22053682

Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP
Journal Article · Thu Feb 14 23:00:00 EST 2008 · Review of Scientific Instruments · OSTI ID:21103896