Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Monte Carlo study of photon fields from a flattening filter-free clinical accelerator

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2174720· OSTI ID:20775121
; ; ; ; ;  [1]
  1. University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States)
In conventional clinical linear accelerators, the flattening filter scatters and absorbs a large fraction of primary photons. Increasing the beam-on time, which also increases the out-of-field exposure to patients, compensates for the reduction in photon fluence. In recent years, intensity modulated radiation therapy has been introduced, yielding better dose distributions than conventional three-dimensional conformal therapy. The drawback of this method is the further increase in beam-on time. An accelerator with the flattening filter removed, which would increase photon fluence greatly, could deliver considerably higher dose rates. The objective of the present study is to investigate the dosimetric properties of 6 and 18 MV photon beams from an accelerator without a flattening filter. The dosimetric data were generated using the Monte Carlo programs BEAMnrc and DOSXYZnrc. The accelerator model was based on the Varian Clinac 2100 design. We compared depth doses, dose rates, lateral profiles, doses outside collimation, total and collimator scatter factors for an accelerator with and without a flatteneing filter. The study showed that removing the filter increased the dose rate on the central axis by a factor of 2.31 (6 MV) and 5.45 (18 MV) at a given target current. Because the flattening filter is a major source of head scatter photons, its removal from the beam line could reduce the out-of-field dose.
OSTI ID:
20775121
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 4 Vol. 33; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Monte Carlo study of backscatter in a flattening filter free clinical accelerator
Journal Article · Fri Sep 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:20853445

A flattening filter free photon treatment concept evaluation with Monte Carlo
Journal Article · Thu Jun 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:20853175

Properties of unflattened photon beams shaped by a multileaf collimator
Journal Article · Thu Jun 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:20853187