In vivo dosimetry with MOSFETs: Dosimetric characterization and first clinical results in intraoperative radiotherapy
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Unita Operativa di Fisica Sanitaria, H.S. Filippo Neri, Rome (Italy)
- Laboratorio di Fisica Medica, Istituto Regina Elena, Rome (Italy)
Purpose: To investigate the use of metal oxide silicon field effect transistors (MOSFETs) as in vivo dosimetry detectors during electron beams at high dose-per-pulse intraoperative radiotherapy. Methods and Materials: The MOSFET system response in terms of reproducibility, energy, dose rate and temperature dependence, dose-linearity from 1 to 25 Gy, angular response, and dose perturbation was analyzed in the 6-9-MeV electron beam energy range produced by an intraoperative radiotherapy-dedicated mobile accelerator. We compared these with the 6- and 9-MeV electron beams produced by a conventional accelerator. MOSFETs were also used in clinical dosimetry. Results: In experimental conditions, the overall uncertainty of the MOSFET response was within 3.5% ({+-}SD). The investigated electron energies and the dose rate did not significantly influence the MOSFET calibration factors. The dose perturbation was negligible. In vivo dosimetry results were in accordance with the predicted values within {+-}5%. A discordance occurred either for an incorrect position of the dosimeter on the patient or when a great difference existed between the clinical and calibration setup, particularly when performing exit dose measurements. Conclusion: Metal oxide silicon field effect transistors are suitable for in vivo dosimetry during intraoperative radiotherapy because their overall uncertainty is comparable to the accuracy required in target dose delivery.
- OSTI ID:
- 20702215
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 3 Vol. 63; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
In Vivo Dosimetry for Single-Fraction Targeted Intraoperative Radiotherapy (TARGIT) for Breast Cancer
Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system
Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer
Journal Article
·
Sun Apr 01 00:00:00 EDT 2012
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:22056287
Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system
Journal Article
·
Thu Apr 15 00:00:00 EDT 2010
· Medical Physics
·
OSTI ID:22098509
Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer
Journal Article
·
Wed Aug 15 00:00:00 EDT 2007
· Medical Physics
·
OSTI ID:20953496