Relative biologic effectiveness determination in mouse intestine for scanning proton beam at Paul Scherrer Institute, Switzerland. Influence of motion
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Universite catholique de Louvain, Brussels (Belgium)
- Paul Scherrer Institute, Villigen (Switzerland)
Purpose To determine the relative biologic effectiveness (RBE) of the Paul Scherrer Institute (PSI) scanning proton beam in reference conditions and to evaluate the influence of intestine motion on the proton dose homogeneity. Methods and Materials: First, RBE was determined for crypt regeneration in mice after irradiation in a single fraction. Irradiation was performed at the middle of a 7-cm spread out Bragg peak (SOBP; reference position), as well as in the proximal part of the plateau and at the distal end of the SOBP. Control {gamma}-irradiation was randomized with proton irradiation and performed simultaneously. Second, motion of mouse intestine was determined by radiographs after copper wire markers had been placed on the jejunum and intestinal wall. Results: Proton RBE (reference {sup 60}Co {gamma}) was equal to 1.16 for irradiation at the middle of the SOBP and to 1.11 and 1.21 for irradiation in the initial plateau and end of the SOBP, respectively. The confidence intervals for these RBE values were much larger than those obtained in the other proton beams we have tested so far. They exceeded {+-}0.20 (compared with the usual value of {+-}0.07), which resulted from the unusually large dispersion of the individual proton data. The instantaneous positions of the mice intestines varied by {+-}2 mm in the course of irradiation. Conclusion: The results of this study have shown that the RBE of the PSI proton beam is in total accordance with the RBE obtained at the other centers. This experiment has corroborated that proton RBE at the middle of the SOBP is slightly larger than the generic value of 1.10 and that there is a slight tendency for the RBE to increase close to the end of the SOBP. Also, excessive dispersion of individual proton data may be considered to result from intestine motion, taking into account that irradiation at the PSI is delivered dynamically by scanning the target volume with a pencil proton beam ('spot scanning'). Because 2-mm movements resulted in significant variations in local dose depositions, this should be considered for moving targets. Strategies to reduce this effect for the spot scanning technique have been developed at the PSI for radiotherapy of humans.
- OSTI ID:
- 20698587
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 3 Vol. 62; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurements of radiobiological effectiveness in the 85 MeV proton beam produced at the cyclotron CYCLONE of Louvain-la-Neuve, Belgium
In vivo determinations of RBE in a high energy modulated proton beam using normal tissue reactions and fractionated dose schedules
In Vivo Radiobiological Characterization of Proton Beam at the National Cancer Center in Korea: Effect of the Chk2 Mutation
Journal Article
·
Sun Dec 31 23:00:00 EST 1995
· Radiation Research
·
OSTI ID:478300
In vivo determinations of RBE in a high energy modulated proton beam using normal tissue reactions and fractionated dose schedules
Journal Article
·
Fri Dec 31 23:00:00 EST 1976
· Int. J. Radiat. Oncol., Biol. Phys.; (United States)
·
OSTI ID:7090272
In Vivo Radiobiological Characterization of Proton Beam at the National Cancer Center in Korea: Effect of the Chk2 Mutation
Journal Article
·
Mon Jan 31 23:00:00 EST 2011
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:21499714