skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Esophagus sparing with IMRT in lung tumor irradiation: An EUD-based optimization technique

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [1];  [1];  [1];  [1]
  1. University of Michigan, Department of Radiation Oncology, Ann Arbor, MI (United States)

Purpose: The aim of this study was to evaluate (1) the use of generalized equivalent uniform dose (gEUD) to optimize dose escalation of lung tumors when the esophagus overlaps the planning target volume (PTV) and (2) the potential benefit of further dose escalation in only the part of the PTV that does not overlap the esophagus. Methods and Materials: The treatment-planning computed tomography (CT) scans of patients with primary lung tumors located in different regions of the left and right lung were used for the optimization of beamlet intensity modulated radiation therapy (IMRT) plans. In all cases, the PTV overlapped part of the esophagus. The dose in the PTV was maximized according to 7 different primary cost functions: 2 plans that made use of mean dose (MD) (the reference plan, in which the 95% isodose surface covered the PTV and a second plan that had no constraint on the minimum isodose), 3 plans based on maximizing gEUD for the whole PTV with ever increasing assumptions for tumor aggressiveness, and 2 plans that used different gEUD values in 2 simultaneous, overlapping target volumes (the whole PTV and the PTV minus esophagus). Beam arrangements and NTCP-based costlets for the organs at risk (OARs) were kept identical to the original conformal plan for each case. Regardless of optimization method, the relative ranking of the resulting plans was evaluated in terms of the absence of cold spots within the PTV and the final gEUD computed for the whole PTV. Results: Because the MD-optimized plans lacked a constraint on minimum PTV coverage, they resulted in cold spots that affected approximately 5% of the PTV volume. When optimizing over the whole PTV volume, gEUD-optimized plans resulted in higher equivalent uniform PTV doses than did the reference plan while still maintaining normal-tissue constraints. However, only under the assumption of extremely aggressive tumors could cold spots in the PTV be avoided. Generally, high-level overall results are obtained when optimization in the whole PTV is also associated with a second simultaneous optimization in the PTV minus overlapping portions of the esophagus. Conclusions: Intensity modulated radiation therapy optimizations that utilize gEUD-based cost functions for the PTV and NTCP-based constraints for the OARs result in increased doses to large portions of the PTV in cases where the PTV overlaps the esophagus, while still maintaining (and confining to the overlap region) minimum dose coverage equivalent to the homogeneous PTV optimization cases.

OSTI ID:
20698539
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 63, Issue 1; Other Information: DOI: 10.1016/j.ijrobp.2005.01.028; PII: S0360-3016(05)00156-2; Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Multiple fields may offer better esophagus sparing without increased probability of lung toxicity in optimized IMRT of lung tumors
Journal Article · Mon May 01 00:00:00 EDT 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20698539

Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors
Journal Article · Wed Jun 01 00:00:00 EDT 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20698539

Superiority of Equivalent Uniform Dose (EUD)-Based Optimization for Breast and Chest Wall
Journal Article · Thu Apr 01 00:00:00 EDT 2010 · Medical Dosimetry · OSTI ID:20698539