Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Effect of image uncertainty on the dosimetry of trigeminal neuralgia irradiation

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [2];  [1]
  1. Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States)
  2. Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI (United States)

Objective: Our objective was to quantify the uncertainty in localization of the trigeminal nerve (TGN) with magnetic resonance imaging (MRI) and computed tomography (CT) and to determine the effect of this uncertainty on gamma-knife dose delivery. Methods: An MR/CT test phantom with 9, 0.6-mm diameter, copper rings was devised. The absolute ring positions in stereotactic space were determined by the angiographic module of the LGP software. The standard deviation, {sigma}, in the difference between the absolute and MR-measured or CT-measured coordinates of the rings was determined. The trigeminal nerve in 52 previously treated patients was contoured and expanded by 1{sigma} and 2{sigma} margins to model the uncertainty in the location of the nerve. For gamma-knife treatment, a single isocenter was used and was located at the distal cisternal portion of the trigeminal nerve root. Irradiation methods included a 4-mm collimator, 90 Gy to isocenter and a 4 and 8-mm collimator, 70 Gy to isocenter. A patient outcome survey that sampled pain relief and morbidity was done. Results: The MR coordinate {sigma} was 0.7 mm left-right, 0.8 mm anterior-posterior, and 0.6 mm superior-inferior, and the CT coordinate {sigma} was 0.4 mm left-right, 0.2 mm anterior-posterior, and 0.2 mm superior-inferior. A 45% higher dose line covered the TGN with the 4 and 8-mm method. No significant increase in pain reduction or morbidity occurred. Conclusions: The uncertainty of target location by MRI is more than twice that found in CT imaging. The 4 and 8-mm collimator method covers the trigeminal root cross section with a higher isodose line than does the 4-mm method. This higher dose did not significantly reduce pain or increase morbidity.

OSTI ID:
20698519
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 5 Vol. 62; ISSN IOBPD3; ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Clinical Evaluation of Targeting Accuracy of Gamma Knife Radiosurgery in Trigeminal Neuralgia
Journal Article · Fri Nov 30 23:00:00 EST 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21039676

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia
Journal Article · Sat Nov 01 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22317939

Where to locate the isocenter? The treatment strategy for repeat trigeminal neuralgia radiosurgery
Journal Article · Sun May 01 00:00:00 EDT 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20698406