Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparison of intensity-modulated radiotherapy with three-dimensional conformal radiation therapy planning for glioblastoma multiforme

Journal Article · · Medical Dosimetry

This study was designed to assess the feasibility and potential benefit of using intensity-modulated radiotherapy (IMRT) planning for patients newly diagnosed with glioblastoma multiforme (GBM). Five consecutive patients with confirmed histopathologically GBM were entered into the study. These patients were planned and treated with 3-dimensional conformal radiation therapy (3DCRT) using our standard plan of 3 noncoplanar wedged fields. They were then replanned with the IMRT method that included a simultaneous boost to the gross tumor volume (GTV). The dose distributions and dose-volume histograms (DHVs) for the planning treatment volume (PTV), GTV, and the relevant critical structures, as obtained with 3DCRT and IMRT, respectively, were compared. In both the 3DCRT and IMRT plans, 59.4 Gy was delivered to the GTV plus a margin of 2.5 cm, with doses to critical structures below the tolerance threshold. However, with the simultaneous boost in IMRT, a higher tumor dose of {approx}70 Gy could be delivered to the GTV, while still maintaining the uninvolved brain at dose levels of the 3DCRT technique. In addition, our experience indicated that IMRT planning is less labor intensive and time consuming than 3DCRT planning. Our study shows that IMRT planning is feasible and efficient for radiotherapy of GBM. In particular, IMRT can deliver a simultaneous boost to the GTV while better sparing the normal brain and other critical structures.

OSTI ID:
20655464
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 4 Vol. 28; ISSN 0958-3947; ISSN MEDOEJ
Country of Publication:
United States
Language:
English

Similar Records

SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22648990

Impact of Gastric Filling on Radiation Dose Delivered to Gastroesophageal Junction Tumors
Journal Article · Sat May 01 00:00:00 EDT 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21372272

Esophageal Cancer Dose Escalation Using a Simultaneous Integrated Boost Technique
Journal Article · Sat Dec 31 23:00:00 EST 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22055980