skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Large Cryogenic Infrastructure for LHC Superconducting Magnet and Cryogenic Component Tests: Layout, Commissioning and Operational Experience

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.1774685· OSTI ID:20653152
; ; ; ;  [1]
  1. Accelerator Technology Division, CERN, 1211 Geneva 23 (Switzerland)

The largest cryogenic test facility at CERN, located at Zone 18, is used to validate and to test all main components working at cryogenic temperature in the LHC (Large Hadron Collider) before final installation in the machine tunnel. In total about 1300 main dipoles, 400 main quadrupoles, 5 RF-modules, eight 1.8 K refrigeration units will be tested in the coming years.The test facility has been improved and upgraded over the last few years and the first 18 kW refrigerator for the LHC machine has been added to boost the cryogenic capacity for the area via a 25,000 liter liquid helium dewar. The existing 6 kW refrigerator, used for the LHC Test String experiments, will also be employed to commission LHC cryogenic components.We report on the design and layout of the test facility as well as the commissioning and the first 10,000 hours operational experience of the test facility and the 18 kW LHC refrigerator.

OSTI ID:
20653152
Journal Information:
AIP Conference Proceedings, Vol. 710, Issue 1; Conference: CEC 2003: Cryogenic engineering and international cryogenic materials conference on advances in cryogenic engineering, Anchorage, AK (United States), 22-26 Sep 2003; Other Information: DOI: 10.1063/1.1774685; (c) 2004 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English