New configuration of photoconductive-type diamond detector head for X-ray beam position monitors
Journal Article
·
· AIP Conference Proceedings
- SPring-8 / JASRI, 1-1-1 Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5198 (Japan)
We designed and fabricated new diamond detector head for an X-ray beam position monitor (XBPM). This monitor operates in photoconductive mode, and is shaped into a blade in order to reduce heat load. A pair of aluminum electrodes is formed on both sides of the diamond blade. The profile of the detection efficiency inside the diamond detector head was measured. The signal current is generated only between the pair of electrodes. The bias voltage dependence of signal current along a section of the detector head is also measured. The results show that the detector head operates in photoconductive mode. We demonstrated that this detector head is feasible for the XBPM.
- OSTI ID:
- 20653108
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 705; ISSN 0094-243X; ISSN APCPCS