A Novel Active Grating Monochromator - Active Grating Spectrometer Beamline System for Inelastic Soft-X-ray Scattering Experiments
- National Synchrotron Radiation Research Center, Hsinchu 30077, Taiwan (China)
By using two aspherical variable-line-space active gratings and applying the energy compensation principle, we have designed a very efficient active grating monochromator -- active grating spectrometer (AGM-AGS) beamline system for the photon demanding inelastic soft-x-ray scattering experiments. During the energy scan, the defocus and coma aberrations of the AGM can be completely eliminated to make the focal point fixed at the sample position and to maintain high spectral resolution for the entire spectral range. The AGS, which has an optical system identical to that of the AGM, but positioned reversely along the optical path, collects the photons emitted from the sample with a nearly identical energy spread as the AGM and focus them onto a position sensitive detector located at the exit slit position. The ray tracing results show that the efficiency of the AGM-AGS is two orders of magnitudes higher than that of conventional design while maintaining a very high spectral resolution.
- OSTI ID:
- 20653033
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 705; ISSN 0094-243X; ISSN APCPCS
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design of Grazing Incident Monochromator for Saga Synchrotron Light
VUV-SX spherical grating monochromator for BEPC beamline 4B9B