The Present Status of Siam Photon Laboratory
- National Synchrotron Research Center, Technopolis, 111 University Avenue, Muang District, Nakhon Ratchasima 30000 (Thailand)
We report the technical problems encountered in commissioning and improving the performance of the accelerator complex which consists of a 1 GeV light source storage ring, a 1 GeV booster synchrotron, and a 40 MeV injector linac. Regulation work for an attached beam line with an experimental station for photoemission studies is also described. Beam instability and low injection efficiency are the major issues for the accelerator complex. In the beam line, the accurate optical alignment of the monochromator system and the modification of the measurement control software supplied by a marker are the work having been performed. The results of the work on the accelerator complex will be helpful to the commissioning of the machine obtained secondhand and reformed to some extent.
- OSTI ID:
- 20652958
- Journal Information:
- AIP Conference Proceedings, Vol. 705, Issue 1; Conference: 8. international conference on synchrotron radiation instrumentation, San Francisco, CA (United States), 25-29 Aug 2003; Other Information: DOI: 10.1063/1.1757728; (c) 2004 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Performance of the BL4 Beamline for Surface and Interface Research at the Siam Photon Laboratory
Commissioning of the soft x-ray undulator beamline at the Siam Photon Laboratory
Related Subjects
BEAM INJECTION
COMMISSIONING
COMPUTER CODES
CONTROL
GEV RANGE 01-10
INSTABILITY
LIGHT SOURCES
LINEAR ACCELERATORS
MEV RANGE 10-100
PARTICLE BEAMS
PERFORMANCE
PHOTOEMISSION
PHOTONS
REGULATIONS
STORAGE RINGS
SYNCHROTRON RADIATION
SYNCHROTRONS
THAILAND
ULTRAVIOLET RADIATION
X RADIATION