Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Status of PF-AR

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.1757727· OSTI ID:20652948
The PF-AR is a full-time single-bunch light source for SR experiments in the X-ray region. Electrons are injected at 3.0 GeV and ramped up to the final energy of 6.5 GeV for normal user operation or 5.0 GeV for medical application. The typical initial beam current is 55 mA at 6.5 GeV and the beam lifetime is 15 h at 50 mA. The initial single-bunch impurity better than 10-8 was achieved, however, degradation of the impurity during the users' run has to be solved. Since the present emittance of 290nm{center_dot}rad is not satisfactory, we are making an effort to realize the minimum attainable emittance of 160nm{center_dot}rad. The high quality of pulse X-ray has brought us abundant occasions to do time-domain and/or time-resolved measurements.
OSTI ID:
20652948
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 705; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Status of the 6.5-GeV Photon Factory Advanced Ring
Journal Article · Thu Jan 18 23:00:00 EST 2007 · AIP Conference Proceedings · OSTI ID:21052671

OPERATION OF LOW EMITTANCE LATTICE AT THE NSLS X-RAY RING.
Conference · Sun Mar 28 23:00:00 EST 1999 · OSTI ID:15016694

Status of PLS-II Upgrade Program
Journal Article · Wed Jun 23 00:00:00 EDT 2010 · AIP Conference Proceedings · OSTI ID:21410224