skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SPECT brain imaging of the dopaminergic system in Parkinsonism using {sup 123}I and {sup 99m}Tc labeled agents

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.1820014· OSTI ID:20634545
 [1]
  1. Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States)

SPECT brain imaging of the dopaminergic system using {sup 123}I and {sup 99m}Tc labeled agents, especially the simultaneous imaging of both pre- and postsynaptic neurons, promises to provide accurate diagnosis and differentiation of Parkinsonism. However, there are many degrading factors that affect the quality and quantitative accuracy of the SPECT images. These degrading factors limit the potential clinical applications of brain SPECT imaging. In this work, we studied these degrading factors by developing and validating a Monte Carlo (MC) method that provides accurate SPECT simulation with detailed modeling of the photon interactions inside the collimator detector system. To compensate for the partial volume effect (PVE) in the SPECT images caused by finite spatial resolution, we developed a new PVE compensation method that takes into account the effects of nonlinearity in iterative reconstruction-based compensation for image degrading factors, including attenuation, scatter, and collimator detector response. Compensation using the new method greatly improved the quantitative accuracy of brain SPECT images. We have also developed model-based method that can accurately estimate the downscatter and crosstalk contamination in the {sup 123}I imaging and the simultaneous {sup 123}I/{sup 99m}Tc dual-isotope imaging. Based on the model-based method, two different approaches to model-based downscatter and crosstalk contamination compensation were proposed. Both methods are based on iterative reconstruction and include compensation for other imaging degrading factors. The model-based downscatter and crosstalk compensation method provided greatly improved accuracy of activity estimates with little effect on the precision. Finally, optimization of energy windows for simultaneous {sup 123}I/{sup 99m}Tc acquisition was performed to find the energy windows with the best trade-off between minimizing the crosstalk and maximizing the detection efficiency for simultaneous acquisitions. In summary, comprehensive methods were developed and evaluated to compensate for image degrading factors in simultaneous dual-isotope brain SPECT imaging. Application of these methods in the imaging of the dopaminergic system has the potential to provide improved accuracy for diagnosis of Parkinsonism.

OSTI ID:
20634545
Journal Information:
Medical Physics, Vol. 31, Issue 12; Other Information: DOI: 10.1118/1.1820014; (c) 2004 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language: