Laminar flow heat transfer and pressure drop characteristics of power-law fluids inside tubes with varying width twisted tape inserts
Results of an experimental investigation of heat transfer and flow friction of a generalized power-law fluid in tape generated swirl flow inside a 25.0 mm i.d. circular tube, are presented. In order to reduce excessive pressure drops associated with full width twisted tapes, with less corresponding reduction in heat transfer coefficients, reduced width twisted tapes of widths ranging from 11.0 to 23.8 mm, which are lower than the tube inside diameter are used. Reduced width twisted tape inserts give 18%--56% lower isothermal friction factors than the full width tapes. Uniform wall temperature Nusselt numbers decrease only slightly by 5%--25%, for tape widths of 19.7 and 11.0 mm, respectively. Based on the constant pumping power criterion, the tapes of width 19.7 mm perform more or less like full width tapes. Correlations are presented for isothermal and heating friction factors and Nusselt numbers (under uniform wall temperature condition) for a fully developed laminar swirl flow, which are applicable to full width as well as reduced width twisted tapes, using a modified twist ratio as pitch to width ratio of the tape. The reduced width tapes offer 20%--50% savings in the tape material as compared to the full width tapes.
- Research Organization:
- Bharti Vidyapith's Coll. of Engineering, Maharashtra (IN)
- OSTI ID:
- 20067717
- Journal Information:
- Journal of Heat Transfer, Journal Name: Journal of Heat Transfer Journal Issue: 1 Vol. 122; ISSN 0022-1481; ISSN JHTRAO
- Country of Publication:
- United States
- Language:
- English
Similar Records
Influences of peripherally-cut twisted tape insert on heat transfer and thermal performance characteristics in laminar and turbulent tube flows
The effect of twisted-tape width on heat transfer and pressure drop for fully developed laminar flow
Experimental studies on heat transfer and friction factor characteristics of forced circulation solar water heater system fitted with helical twisted tapes
Journal Article
·
Wed Sep 15 00:00:00 EDT 2010
· Experimental Thermal and Fluid Science
·
OSTI ID:21320537
The effect of twisted-tape width on heat transfer and pressure drop for fully developed laminar flow
Journal Article
·
Mon Jul 01 00:00:00 EDT 1996
· Journal of Engineering for Gas Turbines and Power
·
OSTI ID:372192
Experimental studies on heat transfer and friction factor characteristics of forced circulation solar water heater system fitted with helical twisted tapes
Journal Article
·
Sat Nov 14 23:00:00 EST 2009
· Solar Energy
·
OSTI ID:21236000