Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Role of microstructures on stress corrosion cracking of pipeline steels in carbonate-bicarbonate solution

Journal Article · · Corrosion (Houston)
DOI:https://doi.org/10.5006/1.3284018· OSTI ID:20013146
Stress corrosion cracking (SCC) on the external surface of pipelines contributes to the major failure of pipelines. The great majority of SCC is intergranular and occurs in a carbonate-bicarbonate environment. Metallurgical factors affecting SCC are still vague and therefore have been studied. Uniform microstructures, not mixed structures, are favorable for suppressing SCC. Low-C steels produced in a process such as thermomechanical-controlled processing are less susceptible to SCC. The presence of locally soft microstructures decreases resistance to SCC (mixed structure and decarburized structure). However, SCC resistance is high on hard layers, like grit-blasted surfaces.
Research Organization:
Nippon Steel Corp., Futtsu, Chiba (JP)
OSTI ID:
20013146
Journal Information:
Corrosion (Houston), Journal Name: Corrosion (Houston) Journal Issue: 7 Vol. 55; ISSN 0010-9312; ISSN CORRAK
Country of Publication:
United States
Language:
English

Similar Records

Stress-corrosion cracking steel susceptibility
Conference · Sun Dec 31 23:00:00 EST 1978 · OSTI ID:6336376

Effects of surface condition on the stress corrosion cracking of line pipe steel
Journal Article · Thu Mar 31 23:00:00 EST 1988 · Mater. Performance; (United States) · OSTI ID:5001191

Initiation of stress corrosion cracking for pipeline steels in a carbonate-bicarbonate solution
Journal Article · Sun Sep 01 00:00:00 EDT 1996 · Metallurgical and Materials Transactions. A, Physical Metallurgy and Materials Science · OSTI ID:382520