Test results of an absorption heat pump with adjustable composition
Conference
·
OSTI ID:20002353
A test rig of an advanced absorption heat pump (AHP) for domestic heating has been built and tested in steady-state operation. The AHP is intended to replace conventional boilers used in hot water heating systems, which are very common in Europe and gaining more interest in the United States. To be competitive against conventional boilers, the AHP must be adaptable to different heat sources and heating systems. An attractive heat source is ambient air, which is easily accessible at relatively low cost. The main disadvantage of ambient air is the greater variation in daily and seasonal temperature and the lower temperature compared to other heat sources such as ground heat. A power controlled AHP with adjustable composition is proposed to match these challenging conditions. A single-stage absorption heat pump was chosen as the base for the development. To enable a monovalent system (i.e., the AHP is the only device to provide heat) and to permit operation at heat source temperatures below 0 C (32 F), ammonia-water has been chosen as the working pair. The absorption heat pump consists of a generator, which possesses a storage volume for strong solution, a solution heat exchanger combined with a solution-cooled partial condenser, a condenser, a precooler, an evaporator, an absorber, a solution pump, and refrigerant storage. The AHP is designed for a maximum heating capacity of 20 kW (68000 Btu/h) at {minus}15 C (5 F). The maximum hot water temperature is 55 C (131 F). The burner, the solution valve, and the expansion valve are continuously adjustable. The storage allows shifting the mass fraction of the strong solution from 17 mass% to 50 mass%. The combined partial-condenser/solution heat exchanger works well at mass fractions from 25 mass% to 50 mass%. This corresponds to heat source temperatures from {minus}10 C (14 F) to 10 C (50 F), whereby a maximum hot water temperature of 55 C (13 F) is possible. Within this range, the process heating coefficient of performance (COP{sub H}) varies from 1.4 to 1.7. Below {minus}10 C (14 F), the COP{sub H} decreases drastically. It is possible, however, to operate the AHP in heat pump mode at temperatures as low as {minus}20 C ({minus}4 F).
- Research Organization:
- Inst. of Technical Thermodynamics, Hardthausen (DE)
- Sponsoring Organization:
- Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie
- OSTI ID:
- 20002353
- Report Number(s):
- CONF-990102--; ISSN 0001-2505
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investigation of an ejector heat pump by analytical methods
Experimental evaluation of a semi-open membrane-based absorption heat pump system utilizing ionic liquids
Design of thermodynamic charts for hydrocarbon mixtures and influence of operating temperatures for solar absorption cooling cycle
Technical Report
·
Sun Jul 01 00:00:00 EDT 1984
·
OSTI ID:6890823
Experimental evaluation of a semi-open membrane-based absorption heat pump system utilizing ionic liquids
Journal Article
·
Sat Feb 09 23:00:00 EST 2019
· Applied Energy
·
OSTI ID:1502523
Design of thermodynamic charts for hydrocarbon mixtures and influence of operating temperatures for solar absorption cooling cycle
Journal Article
·
Wed Oct 01 00:00:00 EDT 1997
· Energy Sources
·
OSTI ID:562182