Volatile organic compound analysis in wood combustion and meat cooking emissions

Conference ·
OSTI ID:20002126

Residential wood combustion and meat cooking emissions were each analyzed for volatile organic compounds (VOC). Emissions were diluted 60--100 times, cooled to ambient temperature, and allowed 80 seconds for condensation prior to collection with the aid of a DRI-constructed dilution stack sampler. Fireplace and wood-stove emissions testing was conducted at the DRI facilities. Wood type, wood moisture, burn rate, and fuel load were varied for different experiments. Meat emissions testing was conducted at the CE-CERT stationary emissions lab, University of California, Riverside. Meat type, fat content, and cooking appliance were changed in different tests. VOCs were collected using stainless-steel 6 L canisters and Tenax cartridges, whereas for carbonyl compound collection 2,4-dinitrophenylhydrazine (DNPH)-impregnated C{sub 18} SepPack cartridges were used. Analysis of VOC collected with canisters and Tenax cartridges was conducted by Gas Chromatography/Mass Spectrometry (GC/MS) and by GC/FID/ECD (flame ionization detection/electron capture detection). DNPH-impregnated cartridges were analyzed for fourteen C{sub 1}--C{sub 7} carbonyl compounds, using the HPLC method. The results of these measurements are discussed.

Research Organization:
Desert Research Inst., Reno, NV (US)
OSTI ID:
20002126
Report Number(s):
CONF-990608--
Country of Publication:
United States
Language:
English