Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Effect of mixed convection and u-bends on the design of double-pipe heat exchangers

Journal Article · · Heat Transfer Engineering
For horizontal flow in the laminar flow regimen, the interaction between natural and forced convection and the effect of the secondary flow induced by an unheated U-bend were considered in developing an empirical correlation for the nearly uniform heat flux condition. The correlation predicts the local peripheral average heat transfer coefficient with an absolute average deviation of 9.9%. In this article the mechanisms involved in laminar flow with the presence of a U-bend are explained. The realistic behavior of the correlation is illustrated. Also, a brief discussion of some of the existing correlations for laminar flow is presented. Four cases showing the practicality of using the correlation in the design of horizontal double-pipe heat exchangers are demonstrated.
Research Organization:
Saint Martin's Coll., Lacey, WA (US)
OSTI ID:
20001219
Journal Information:
Heat Transfer Engineering, Journal Name: Heat Transfer Engineering Journal Issue: 3 Vol. 20; ISSN 0145-7632; ISSN HTEND2
Country of Publication:
United States
Language:
English

Similar Records

Laminar-flow heat transfer downstream from U-bends
Thesis/Dissertation · Wed Dec 31 23:00:00 EST 1986 · OSTI ID:6330865

Natural convection heat transfer from helicoidal pipes
Book · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:445509

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe
Technical Report · Fri Sep 01 00:00:00 EDT 1995 · OSTI ID:107025