Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

Journal Article · · International Journal of Mass Spectrometry
In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 1011 vs 1013 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.
Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1995684
Journal Information:
International Journal of Mass Spectrometry, Journal Name: International Journal of Mass Spectrometry Journal Issue: 2023 Vol. 492; ISSN 1387-3806
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (35)

Determination of the isotopic composition of single sub-micrometer-sized uranium particles by laser ablation coupled with multi-collector inductively coupled plasma mass spectrometry journal February 2019
Uranium, Thorium and Anthropogenic Radionuclides as Atmospheric Tracers book June 2011
Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP–MS with multiple ion counters journal September 2007
Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS journal January 2013
Laser ablation research and development: 60 years strong journal February 2023
Performance of laser ablation: quadrupole-based ICP-MS coupling for the analysis of single micrometric uranium particles journal September 2012
Application of laser ablation inductively coupled plasma mass spectrometry for the isotopic analysis of single uranium particles journal September 2008
Low-temperature isotopic fractionation of uranium journal December 2007
Natural fractionation of 238U/235U journal January 2008
Discerning crystal growth from diffusion profiles in zoned olivine by in situ Mg–Fe isotopic analyses journal December 2013
Uranium isotopic compositions of the crust and ocean: Age corrections, U budget and global extent of modern anoxia journal October 2015
238U, 235U and 234U in seawater and deep-sea corals: A high-precision reappraisal journal November 2022
Reconstructing the chronology of the natural and anthropogenic uranium isotopic signals in a marine sediment core from Beppu Bay, Japan journal April 2023
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclides journal April 2005
Development and comparison of high accuracy thermal ionization mass spectrometry methods for uranium isotope ratios determination in nuclear fuel journal April 2019
Direct uranium isotope ratio analysis of single micrometer-sized glass particles journal November 2012
Spatial distribution of uranium isotopes in solid nuclear materials using laser ablation multi-collector ICP-MS journal July 2018
Insights into secondary ion formation during dynamic SIMS analysis: Evidence from sputtering of laboratory synthesized uranium compounds with a high-energy O− primary beam on a NanoSIMS 50L
  • Zirakparvar, N. Alex; Spano, Tyler L.; Miskowiec, Andrew
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 502 https://doi.org/10.1016/j.nimb.2021.06.007
journal September 2021
Improving Precision and Signal/Noise Ratios for MC-ICP-MS journal January 2015
Application of Nanosecond-UV Laser Ablation–Inductively Coupled Plasma Mass Spectrometry for the Isotopic Analysis of Single Submicrometer-Size Uranium Particles journal September 2011
Improving Precision and Accuracy of Isotope Ratios from Short Transient Laser Ablation-Multicollector-Inductively Coupled Plasma Mass Spectrometry Signals: Application to Micrometer-Size Uranium Particles journal April 2016
Progress in Uranium Chemistry: Driving Advances in Front-End Nuclear Fuel Cycle Forensics journal February 2021
Femtosecond laser ablation multicollector ICPMS analysis of uranium isotopes in NIST glass journal January 2015
Linearity testing and dead-time determination for MC-ICP-MS ion counters using the IRMM-072 series of uranium isotope reference materials journal January 2016
Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry journal January 2018
Capabilities of laser ablation – ICP-TOF-MS coupling for isotopic analysis of individual uranium micrometric particles journal January 2018
Advances in age-dating of individual uranium particles by large geometry secondary ion mass spectrometry journal January 2019
Correlating nanoscale secondary ion mass spectrometry and atom probe tomography analysis of uranium enrichment in metallic nuclear fuel journal January 2021
In situ isotopic analysis of uranium using a new data acquisition protocol for 1013 ohm Faraday amplifiers journal January 2021
Rapid isotopic analysis of uranium particles by laser ablation MC-ICP-MS journal January 2023
Precise and accurate isotopic analysis of microscopic uranium-oxide grains using LA-MC-ICP-MS
  • Lloyd, Nicholas S.; Parrish, Randall R.; Horstwood, Matthew S. A.
  • Journal of Analytical Atomic Spectrometry, Vol. 24, Issue 6 https://doi.org/10.1039/b819373h
journal January 2009
Uranium kernel formation via internal gelation journal January 2004
Unlocking the Single-Crystal Record of Heavy Stable Isotopes journal December 2021
Uranium Isotope Fractionation journal January 2017
Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry journal June 2012

Similar Records

Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS
Journal Article · Sun Mar 16 20:00:00 EDT 2025 · Journal of Analytical Atomic Spectrometry · OSTI ID:2533618