Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Journal Article · · Sustainability (Basel)
DOI:https://doi.org/10.3390/su151612131· OSTI ID:1994222

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

Research Organization:
Arizona State University, Mesa, AZ (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
Grant/Contract Number:
EE0008565
OSTI ID:
1994222
Alternate ID(s):
OSTI ID: 2007051
Journal Information:
Sustainability (Basel), Journal Name: Sustainability (Basel) Journal Issue: 16 Vol. 15; ISSN SUSTDE; ISSN 2071-1050
Publisher:
MDPI AGCopyright Statement
Country of Publication:
Switzerland
Language:
English

References (39)

Investigation of damage caused by partial shading of CuInxGa (1-x) Se 2 photovoltaic modules with bypass diodes : Investigation of damage caused by partial shading journal April 2016
Photovoltaic failure and degradation modes: PV failure and degradation modes
  • Jordan, Dirk C.; Silverman, Timothy J.; Wohlgemuth, John H.
  • Progress in Photovoltaics: Research and Applications, Vol. 25, Issue 4 https://doi.org/10.1002/pip.2866
journal January 2017
An investigation into hot-spots in two large grid-connected PV plants journal December 2008
Loss analysis and optimization of PV module components and design to achieve higher energy yield and longer service life in desert regions journal December 2020
Why Do PV Modules Fail? journal January 2012
Light-induced Degradation of Silicon Solar Cells with Aluminiumoxide Passivated Rear Side journal August 2015
The Performance of Double Glass Photovoltaic Modules under Composite Test Conditions journal September 2017
Close examination of localized hot spots within photovoltaic modules journal April 2021
Investigation and analysis of finger breakages in commercial crystalline silicon photovoltaic modules under standard thermal cycling test journal July 2019
Reliability evaluation of DC power optimizers for photovoltaic systems: Accelerated testing at high temperatures with fixed and cyclic power stresses journal October 2023
Assessment of the electrical and thermal performances of building integrated bifacial photovoltaic modules journal September 2021
Evaluation based on performance and failure of PV system in 10 years field-aged 1 MW PV power plant journal November 2020
Current limiter circuit to avoid photovoltaic mismatch conditions including hot-spots and shading journal January 2020
Faults and infrared thermographic diagnosis in operating c-Si photovoltaic modules: A review of research and future challenges journal September 2016
Heat transfer modeling and temperature experiments of crystalline silicon photovoltaic modules journal April 2017
A bypass circuit for avoiding the hot spot in PV modules journal March 2019
Hotspot diagnosis for solar photovoltaic modules using a Naive Bayes classifier journal September 2019
A novel electrical approach to protect PV modules under various partial shading situations journal November 2019
Study of manufacturing and hotspot formation in cut cell and full cell PV modules journal June 2020
A machine learning framework to identify the hotspot in photovoltaic module using infrared thermography journal September 2020
Impact of cracks on crystalline silicon photovoltaic modules temperature distribution journal September 2021
Research on hot spot risk of high wattage solar modules journal December 2021
Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling journal January 2023
Potential induced degradation in c-Si glass-glass modules after extended damp heat stress journal April 2023
Root cause analysis on corrosive potential-induced degradation effects at the rear side of bifacial silicon PERC solar cells journal October 2019
A comparative life cycle assessment of silicon PV modules: Impact of module design, manufacturing location and inventory journal September 2021
Finger and interconnect degradations in crystalline silicon photovoltaic modules: A review journal September 2021
Rapid testing on the effect of cracks on solar cells output power performance and thermal operation journal July 2022
Long-term reliability of silicon wafer-based traditional backsheet modules and double glass modules journal January 2015
Partial shading detection and hotspot prediction in photovoltaic systems based on numerical differentiation and integration of the PV curves journal October 2022
Investigation of damp heat effects on glass properties for photovoltaic applications journal November 2016
Glass/glass photovoltaic module reliability and degradation: a review journal August 2021
Reliability of copper-ribbons in photovoltaic modules under thermo-mechanical loading conference June 2010
Low cost high energy yield solar module lines and its applications conference June 2015
Insulation or Irradiance: Exploring Why Bifacial Photovoltaics Run Hot conference June 2021
Data-Driven Detection of Hot Spots in Photovoltaic Energy Systems journal August 2019
Long Term Reliability of Photovoltaic Modules conference May 2006
Degradation Effects in sc -­‐ Si PV Modules Subjected to Natural and Induced Ageing after Several Years of Field Operation journal December 2012
Mitigation of Hot-Spots in Photovoltaic Systems Using Distributed Power Electronics journal March 2018

Similar Records

Potential induced degradation in c-Si glass-glass modules after extended damp heat stress
Journal Article · Tue Mar 14 20:00:00 EDT 2023 · Solar Energy · OSTI ID:2007050

Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling
Journal Article · Sun Dec 11 19:00:00 EST 2022 · Solar Energy · OSTI ID:2007054